Installation and Operating Instructions ECOVARIO® 616, 616 D
42
Subject to change without notice!
6.6
Serial interfaces
6.6.1
X13: RS485/RS232 interface with 2 Capture Inputs
Th e ECOVARIO® is available with RS485 or RS232 interface with 2 capture inputs for fast position capturing.
ECOVARIO® 6 xx x x-A x-xxx xxx: design with RS485 interface
ECOVARIO® 6 xx x x-F x-xxx xxx: design with RS485 interface
ECOVARIO® 6 xx x x-B x-xxx xxx: design with RS232 interface
ECOVARIO® 6 xx x x-G x-xxx xxx: design with RS232 interface
Design with RS485 interface
Fig. 6.25: Mating connector X13:
9-poliger D-Sub-Stecker; Ansicht
auf die Löt- bzw. Crimpseite
Apart from the serial interface the connector X13 provides at ECOVARIO® 6xx additionally two capture
inputs with RS422 signal transmission for rapid capture of process events. Th e capture inputs are not galva-
nically separated and can also be confi gured as digital inputs.
Th e RS485 interface of the ECOVARIO® may as well serve for a 4-conductor (full duplex) as also a 2-con-
ductor (half duplex) connector. Transmitter and receiver of the ECOVARIO® meet the specifi cations of EIA-
RS485 (up to 250 kBaud) and are EMC-protected according to IEC 61 000-4-4.
Th e communication protocol allows network operation with a master (host) and up to 126 ECOVARIO®
units as slaves in an RS485 network. At most 32 participants may take part in one network. Th e network
must have a bus structure.
Th e adress (ID) of an ECOVARIO® is set by the front keys. Each ID may only be allocated once. ID = 0 is
reserved and may not be allocated.
Pin
Signal
Description
1
CAP1+
Capture input1 (RS422 level)
2
Rx+
Receive RS485
3
Tx+
Transmit RS485
4
CAP2+
Capture input2 (RS422 level)
5
DGND
Digital ground
6
CAP1-
Capture input1 (RS422 level)
7
Rx-
Receive RS485
8
Tx-
Transmit RS485
9
CAP2-
Capture input2 (RS422 level)
Table 6.18: Pin assignment connector X13