Subject to change without notice!
Installation and Operating Instructions ECOVARIO® 616, 616 D
31
6.3.2
X5A/X5B: Motor connection
1 2 3 4
Using long cables (>25 m) the losses rise
strongly due to the cable capacity. Th ere-
fore with long cables the technical data
of the drive are reduced, further too high
leakage currents can lead to indeliberare
activation of the circuit breakers (see
chap. 5.2.5 „Operation with residual cur-
rent devices“).
For all available types of cable see chap.
9.5.
Connection of motor and brake with
one cable
Th e insulated meshes of the overall shield
and of the shield of the brake cable must
in any case be connected to the chasis
earth or protective earth. Due to impro-
per grounding or free mesh dangerous
voltages may occur at the shield.
Fig. 6.8: Mating connector X5A/X5B:
GIC 2,5 HCV/ 4-ST-7,62, Nr. 17 45 64 5 Phoenix
Signal
Keying
Pin 3-phase motor
1
GND
Phase U
U
2
Connection U
Phase V
V
3
Connection V
Phase W
W
4
Connection W
Tabelle 6.7: Pin assignment connector X5A, X5B
Fig. 6.10: Example for connection with stan-
dard cable MOT63-134-523-xxx
Fig. 6.9 X5: Example for connection with standard cable, e.g.
MOT-61-133-523-xxx
Motor
3-phase
Brake
Motor
3-phase