29
............................. includes 1x stainless steel duct clamp, worm drive, hex screw
Optional External Fluid Kit .............................................. 25 l sealed fluid reservoir,
.......................... 1.5 m (4.9 ft.) 8 mm OD, 6 mm ID, silicone tubing, pipetta fitting
Optional Softcover ................................................. Black, heavy duty PVC external,
........................... brushed nylon padding interior, hook and loop fastener system,
.............................................................. 5 in. x 8 in. transparent PAL transit pocket
Installation
Orientation ....................................................................................... Horizontal only
Location........................................................................................ Dry location only
Clearance around machine ............................................................... 60 cm (24 in.)
Ducting ........................................................... Optional, max. length 10 m (32.8 ft.)
Connections
AC Power ........................... Hardwired flexible mains cable, 3 x 4.0 mm
2
(6 AWG),
......................................................................................................... 3.3 m (10.8 ft.)
DMX/RDM in/out ............................................................... 3- and 5-pin locking XLR
Remote control ............................................................................ 3-pin locking XLR
Firmware ................................................................................................ AVR socket
Fluid inlet, low-fog fluid ............................................ Brass barbed hose tail, 6 mm
Fluid outlet, waste .................................................... Brass barbed hose tail, 6 mm
Electrical
AC power ......................................................... 208 - 250 V single phase, 50/60 Hz
Typical power consumption, standby ............................................................. 10 W
Typical power consumption, maximum ....................................................... 3500 W
Power supply unit ......................................... Auto-ranging electronic switch-mode
Integrated resettable circuit breaker ............................ 25 A, 240 V max., 50/60 Hz
Half-cycle RMS inrush current at 230 V, 50 Hz ................................................. 20 A
Typical Power and Current
208 V, 60 Hz .................................................................... 3350 W, 17.8 A, PF 0.96*
220 V, 50 Hz .................................................................... 3350 W, 16.9 A, PF 0.96*
230 V, 50 Hz .................................................................... 3350 W, 15.6 A, PF 0.96*
240 V, 50 Hz .................................................................... 3350 W, 15.2 A, PF 0.96*
*Figures are typical, not maximum. Measurements made at nominal voltage, allow for a
deviation of +/- 10%.
PF = Power Factor
Thermal
Cooling .................................................................................... Forced air, low noise
Maximum ambient temperature (Ta max.) ............................................ 35° C (95° F)
Minimum ambient temperature (Ta min.) ............................................... 5° C (41° F)
Exterior surface temperature, steady state ........................................... 30° C (86° F)
Total heat dissipation, idle (calculated, +/- 10%) ............................... 2241 BTU/hr.
Total heat dissipation, full load (calculated, +/- 10%) ....................... 11430 BTU/hr.
Acoustic
Noise level average, maximum low-fog output ........................................... 61.1 dBA
Noise level average, standby ..................................................................... 54.2 dBA
Approvals
EU Safety ....................................................................................... EN 60335-1+A11
EU EMC ............................................................................. EN 61000-6-1, EN 62233
EU Immunity ................................................................................. EN 61000-6-1+A1