10
Installation and setting up
Installation and setting up
DANGER! DO NOT operate the machine until you have read and observed all
the precautions listed under “Safety information” on page 4.
Locatio n
The machine is designed to be operated in a dry location on the floor and should
be kept in horizontal orientation. The maximum deviation from horizontal is 2°.
Ensure the machine has at least 60 cm (24 in.) clearance all-round and at least
60cm (24 inches) away from combustible and heat-sensitive materials. Ensure
the same distance from the fog output if ducted.
AC power
Before using the machine, ensure that a grounding-type (earthed) power plug
that matches the local power receptacle is installed on the power cable
provided.
This machine has a high earth leakage current and must only be operated from
supplies with ground fault detection set at 30 mA. Only use an industrial
receptacle/plug combination that reliably ensures earth connectivity before line
connection. For example plugs and sockets conforming to any of the following:-
IEC 60309-1
IEC 60309-2
UL 1682/1686
CSA C22.2
For operating from supplies in the range 208 to 250 V, a minimum rated
supply capacity of 20 A is required.
When installing the plug to the machine’s mains cable, follow the plug
manufacturer’s instructions and connect pins as follows:
Yellow and green wire to ground (earth), blue wire to neutral and brown wire to
live.
The table below shows some common pin identification schemes.
wire function
marking
screw
colour
brown live
“L”
yellow
or
brass
blue neutral
“N” silver
green/yellow earth
green