13
Setting Run mod es
The RUN MODE menu sets the operational mode of the machine. Settings are
OFF (shutdown, heaters off), STANDBY (heaters on), TIMER or CONTINUOUS
output mode.
Use the Menu Previous / Next buttons to select the RUN MODE option.
Use the Up/Down buttons to select OFF, STANDBY, TIMER, CONTINUOUS.
Press the Enter button to activate the setting. The display shows SET.
Selecting OFF will disable the heaters and cooling system on the unit engaging
the shutdown procedure of the machine for 160-seconds. During this period the
waste condensate pump will move condensate fluid from the sump in the fog
outlet into the waste condensate reservoir. Empty the waste condensate reservoir
for travel and storage. Repeat if necessary until no more fluid is pumped.
Empty the waste condensate reservoir prior to engaging the OFF
shutdown procedure. It is possible for the shutdown procedure to
produce condensate that could overfill the reservoir if it is already
near capacity.
Setting Low-Fo g output level
Use the Menu Previous / Next buttons to select the FOG LEVEL menu.
Use the Up/Down buttons to select the level from 0% - 100%
Press the Enter button to store the fog output setting. The display shows SET.
If you want to temporarily change the low-fog level, do not press
Enter. The fog setting will go back to its stored value next time the
machine is powered up. This applies to all options.
Setting the Timer
The timer function can be utilized to set the machine’s output to automatically
cycle between an 'On' time interval and an 'Off' time interval. This mode is useful
for maintaining a low level of low-fog in smaller spaces.
READY