24
Maintenance
The condensate collected in the reservoir cannot be re-used. Dispose of it
responsibly.
Whenever you replace or fill the low-fog fluid reservoir, always empty the
condensate reservoir at the same time. The condensate reservoir should have
enough capacity for the condensate generated from a 5 l container of fluid used
at 50% output level. If you are installing the machine or running for long periods,
consider using the optional “External Fluid Kit” which increases the reservoir
capacity to 25 l.
The condensate pumping time of 2 minutes can be adjusted by a Martin Service
Center, if your local conditions require it.
Exter ior cleani ng
Excessive dust, effects fluid, and dirt build-up will degrade performance and
cause overheating and damage to the machine that is not covered by the
product warranty. To maintain adequate cooling, dust must be cleaned from the
outer casing and air vents of the machine periodically.
Isolate the machine from power and allow to cool completely before cleaning.
Internal parts remain hot for a period after use.
•
Remove dust from the air vents with a soft brush, cotton swab, vacuum,
or compressed air.
•
Clean effects fluid residues from the low-fog output of the machine using
a damp cloth.
•
Clean the outer casing with a damp cloth only.
Filter replacement
The machine uses a washable synthetic fiber filter in the intake for the condenser
fans. The filter is located in the top plate of the machine and can be removed for
cleaning or replacement by removing the top cover, held in place with 6x
Pozidriv #2 screws (M5).
To clean the filter, simply wash with warm water and a mild detergent, and allow
to air dry. Filter replacement part: 56210056 - Condenser filter, Dynamic.