27
Status messages
message reason
OFF
The heaters are Off, the unit is shut down. If the countdown
clock is shown this indicates the shutdown procedure is in
progress.
HEAT
The unit is heating up to operating temperature.
READY
The heater is at operating temperature, but Fog is not turned
on (RUN set to STANDBY).
DMX
The heater is at operating temperature and the unit is under
DMX control.
FLUID OUT
Machine out of fluid. Refill the low-fog fluid reservoir and
operate the prime function in the SETTINGS menu
CALIBRATION
ERROR
The machine has detected an error with its calibration settings
and will not operate. Contact Martin Service and Support.
SYSTEM
ERROR
The machine has detected an error in the temperature sensor
and will not operate. Contact Martin Service and Support.