To Fill The Gun From Bulk Container
1.
Remove grease tube from the gun.
2.
Unscrew the grease tube assembly cap from the grease tube
assembly. Pull on the follower handle to extract the follower and
spring from the grease tube assembly.
3.
Insert the open end of the grease tube assembly into lubricant.
Slowly pull the follower handle back while pushing the grease tube
assembly deeper into the lubricant to prevent air pockets from
being pulled into the grease tube assembly.
4.
When the follower rod is fully extended, pull it sideways to latch the
rod groove into the keyhole slot in the grease tube assembly cap.
5.
Screw the grease tube into the gun and release the follower rod from the slot on the end
cap of the tube to allow the follower rod go forward.
6.
Clean any excess grease off the gun body.
Notice: Reset display reading after purging air.
To Fill the Gun with a Filler Pump
1.
A bulk filler fitting will need to be installed in the grease gun head cap (not included).
2.
Replace the pipe plug in the head cap with the bulk loader fitting.
3.
Engage the follower rod with the follower by rotating the follower handle.
4.
Insert the gun filler nipple into the filler pump socket.
5.
Operate the filler pump to fill the container. When the follower rod groove is exposed,
the grease tube assembly is filled. The follower rod will be extended approximately 8
inches (20 cm).
6.
Disengage the follower rod from the follower by rotating the follower handle. Push the
follower rod into the grease tube assembly.
Do not overfill!
Notice: Reset display reading after purging air.
To Expel Air Pockets
(Pressure relief valve)
1.
Free the follower rod from the grease tube assembly cap and depress the vent valve
when pushing the follower rod forward.
2.
Squeeze the switch vent valve several times to operate gun until trapped air is expelled.
Push the follower rod into the grease tube assembly.
1-800-345-4545 jegs.com
Содержание 81026