background image

 

 

 

TROUBLESHOOTING 

Condition

 

Possible Cause  

 

Corrective Action

 

Motor fails to run

 

Battery needs charging. 
Faulty wiring to motor.

 

Recharge battery. 
Remove battery, disassemble 
handle and check wiring for 
loose connection.

 

Pressure Relief Valve 
opens to discharge 
grease

 

Blocked Line. 
Blocked Bearing 
Blocked Grease fitting

 

Check lines, brazing and grease 
fitting to remove or clean 
obstructions. 

 

PowerLuber fails to 
dispense grease

 

Grease tube assembly is out 
of grease. 
Loss of prime. 
Ball check is not functioning.

 

Check that grease tube 
assembly has grease. 
Repeat priming operation. 
Remove, clean and inspect ball 
seat area. 

 

PowerLuber continues to 
lose prime.

 

Air may be trapped in several 
locations in container after 
bulk filling. 
Follower may be binding in 
grease tube assembly.

 

Empty grease tube assembly, 
refill and repeat priming 
instructions. 
Replace grease tube assembly.

 

Battery fails to take a 
charge.

 

Charger may not have power. 
Battery may be bad.

 

Check that receptacle has 
power. 
Replace battery.

 

 

 

                                         1-800-345-4545   jegs.com

 

Содержание 81026

Страница 1: ...n electric shock fire or serious injury 1 Work Area Safety 1 1 Keep work area clean and well lit Cluttered or dark areas invite accidents 1 2 Do not operate cordless grease gun in explosive atmosphere such as in the presence of flammable liquids gases or dust It may ignite the dust or fumes 1 3 Keep children and bystanders away while operating the cordless grease gun Distractions can cause you to ...

Страница 2: ...witch is dangerous and must be repaired 4 2 Disconnect the battery pack from the cordless grease gun before making any adjustment changing accessories 4 3 When battery pack is not in use keep it away from other mental objects like paper clips coins keys nails screws or other small mental objects that can make a connection from one terminal to another Shorting battery terminals together may cause b...

Страница 3: ...e 400g 450g 14oz 16oz lube shuttle C2104 Outlet hose 42inch 10000 Psi 689bar C2105 Outlet coupler 4 jaws C2106 Blow case Plastic Note The declared values are for reference only during actual use of the grease gun values can differ from the declared values depending on the ways in which the tool is used WARNING Do not continue to hold down trigger if grease gun is stalled This could damage the moto...

Страница 4: ... display and grease gun Press A to turn on off the work light LCD Display will turn off after 20 minutes of no action with the grease gun Grease Flow Monitoring Press A with 5 minutes to change the unit from Oz to Gram Flashing red LCD warning the grease is used up Replace grease cartridge or refill tube Prime the grease gun after each refill or grease cartridge changed To prime operate the gun un...

Страница 5: ...rmal household waste Do not expose battery to fire spark or flame Battery liquid may burn Do not use this battery to any other tools Charger Warning The charger is intended for indoor use only Only use for charging the battery with this tool Do not expose charger to rain snow or frost Do not charge battery in damp or wet location Do not abuse power cord Do not attempt to repair power cord Do not o...

Страница 6: ...omplete Solid Green Red light flashing at a fast rate replace battery Charger detected a weak or damaged battery Stop charging battery 3 Disconnect charger from power source and remove battery pack from charger after full charged CAUTION Charge the battery in clean and dry location when temperatures are between 10 to 40 Battery temperature will increase during and shortly after use Battery may not...

Страница 7: ...ew the grease tube assemble from the cordless grease gun 2 Pull back on the follower handle until the follower rod is fully extended and latch the follower rod groove into the slot on the tube end cap of the grease tube 3 Remove the plastic cap from the grease cartridge and insert cartridge into the container tube 4 Remove the pull tab from grease cartridge and screw grease tube into cordless grea...

Страница 8: ... To Fill the Gun with a Filler Pump 1 A bulk filler fitting will need to be installed in the grease gun head cap not included 2 Replace the pipe plug in the head cap with the bulk loader fitting 3 Engage the follower rod with the follower by rotating the follower handle 4 Insert the gun filler nipple into the filler pump socket 5 Operate the filler pump to fill the container When the follower rod ...

Страница 9: ...1 800 345 4545 jegs com ...

Страница 10: ... dispense grease Grease tube assembly is out of grease Loss of prime Ball check is not functioning Check that grease tube assembly has grease Repeat priming operation Remove clean and inspect ball seat area PowerLuber continues to lose prime Air may be trapped in several locations in container after bulk filling Follower may be binding in grease tube assembly Empty grease tube assembly refill and ...

Отзывы: