TROUBLESHOOTING
Condition
Possible Cause
Corrective Action
Motor fails to run
Battery needs charging.
Faulty wiring to motor.
Recharge battery.
Remove battery, disassemble
handle and check wiring for
loose connection.
Pressure Relief Valve
opens to discharge
grease
Blocked Line.
Blocked Bearing
Blocked Grease fitting
Check lines, brazing and grease
fitting to remove or clean
obstructions.
PowerLuber fails to
dispense grease
Grease tube assembly is out
of grease.
Loss of prime.
Ball check is not functioning.
Check that grease tube
assembly has grease.
Repeat priming operation.
Remove, clean and inspect ball
seat area.
PowerLuber continues to
lose prime.
Air may be trapped in several
locations in container after
bulk filling.
Follower may be binding in
grease tube assembly.
Empty grease tube assembly,
refill and repeat priming
instructions.
Replace grease tube assembly.
Battery fails to take a
charge.
Charger may not have power.
Battery may be bad.
Check that receptacle has
power.
Replace battery.
1-800-345-4545 jegs.com
Содержание 81026