LCD Operation
Control Center
Electrical protection: avoid high current draw (more than 40A). The circuit board will shut
down the circuit.
LED shows battery status, pumping speed and grease output.
Operation
2-Speed Selection
Pressing button B switches the grease gun between high and low
pump speed.
“H”- High speed grease output on 150 g/min at 10000 PSI.
“L” - Low speed grease output on 80 g/min at 6000 PSI.
LCD Display & Light
Trigger turns on/off the LCD display and grease gun.
Press A to turn on/off the work light.
LCD Display will turn off after 20 minutes of no action with the grease gun.
Grease Flow Monitoring
Press A with 5 minutes to change the unit from Oz to Gram.
Flashing red LCD warning the grease is used up. Replace grease cartridge or refill tube.
Prime the grease gun after each refill or grease cartridge changed. To prime, operate the
gun until grease flows from hose. Use vent valve to expel air pockets.
Recharge the Battery
LCD display the battery is low. Recharge the battery.
Clear Reading
Press button B for 3 minutes to clear display of the previous reading.