22
Troubleshooting
ISSUE:
Battery voltage is too high (Error 105).
SOLUTION:
Change battery with less voltage than 17.0 volts.
ISSUE:
High current flow the mosfet (Error 106).
SOLUTION:
Check if motor or gears is damaged or jammed. Check wires to motor for short
circuits or exposed connections. Could be problem of unballanced gun upgrade.
ISSUE:
Battery voltage is too low (Error 107).
SOLUTION:
Change or charge battery to have more voltage than 5.5 volts.
ISSUE:
High temperature on the processor (Error 108).
SOLUTI
ON:
check for short circuits on leviathan through the gearbox or damaged parts.
ISSUE:
Motor is disconnected (Error 109).
SOLUTI
ON:
Check motor and contacts for it, if they aren‘t damaged or disconnected.
ISSUE:
Nonfunctional application (Error 200).
SOLUTION:
Program error in the Leviathan. Make update firmware to the newest version.
ISSUE:
Gun suddenly stopped firing.
SOLUTION:
Protection could be activated - check error log. Check battery charge. Check
motor contacts and motor functionality. Check if the safety fuse hasn’t been blown.
ISSUE: The
Leviathan is not visible in the device list in the application.
SOLUTION:
Click to refresh button in the app. Check if battery is charged and connected
into the Leviathan. Enable wireless and location in your phone. Restart mobile app.
ISSUE:
You programmed the Leviathan, now it doesn‘t do what you wanted.
SOLUTION:
Best way is to do
FACTORY RESET
and start again.
ISSUE:
The gun does something strange or nothing.
SOLUTION:
STOP! Release trigger, disconnect battery and search for the problem before-
something will be irreversibly damaged! Contact us at email
.