13
Sensor troubleshooting
First time shooting
1.
Connect battery, after 1s you will feel a short vibration - power-up self-test is complete.
2.
Put the gun into SAFE-nothing happen on trigger pull (if was done selector plate mode).
3.
Put the gun into SEMI and it will fire once.
4.
Put the gun into AUTO and pull the trigger shortly. Gun should fire a burst of 3 rounds.
If you held down the trigger longer the gun will go to auto fire.
5.
If everything works as described, congratulations for the correct installation the Levi-
athan. If not, check what is written in the error log and the
20-22 pages in this manual
6.
Pair phone with Leviathan and update firmware to the newest version.
Keep your app and firmware always up to date!
13.
If any selector position ends in the red
color, its value is too close to another one,
so the position won‘t be set right.
This could be caused by wrong sticker po-
sition or dirt on selector plate or sensor.
It is also possible you didn‘t change se-
lector position during calibration process.
12.
If cycle range has
too high values
,
move sensor slightly higher to be closer
to the sector gear.
If cycle range has
too low values
, move
sensor slightly lower to be further from
the sector gear or clean the sensor.
For that operates with screw in red circle.
WARNING:
Disconnect the battery, when the gun is not in use! Leviathan drains small
amount of current from the battery all the time so it will overdischarge the battery.