Chapter 11
Maintenance and Troubleshooting
Maintenance procedure
User Manual
790000002/00
81
Cleaning the
optical cable
connector
–
Use a non-linting type of paper, such as Joseph paper, soaked in
isopropylic alcohol.
–
Pay particular attention to the polished face of the fiber, rubbing it in
a direction perpendicular to the axis of the fiber.
Cleaning the
optical
connections of the
2000 Platform
–
Squirt a highly volatile solvent (such as isopropylic alcohol) into the
connector.
–
Blow out the connector using a clean dry air supply from an aerosol
can fitted with an extension.
Accessing to
the 2000
Platform
information
On the 2000 Platform, some screens allows to display information on
different elements of the equipment.
To display the information on the 2000 Platform
1
On the
Home
page, validate
Settings
icon to reach the
System
Settings
page.
2
On the right menu keys, press
About
to display the presentation
screen of the 2000 Platform.
General page
The
General
page is displayed by default, and allows to display the
presentation screen, with all the information concerning the software
versions, the hardware options and the module installed.
NOTE
If your module has a universal connector, unscrew its adaptor to
access the ferule.
Fig. 42
General page
2000 Platform English rev00.book Page 81 Lundi, 20. juin 2011 1:47 13
Содержание 2000 Platform
Страница 3: ...2000 Platform English rev00 book Page ii Lundi 20 juin 2011 1 47 13...
Страница 5: ...2000 Platform English rev00 book Page iv Lundi 20 juin 2011 1 47 13...
Страница 121: ...Index User Manual 790000002 00 102 2000 Platform English rev00 book Page 102 Lundi 20 juin 2011 1 47 13...
Страница 122: ...2000 Platform English rev00 book Page 103 Lundi 20 juin 2011 1 47 13...