Chapter 9
Technical specifications
Environment
72
User Manual
790000002/00
Environment
Temperature
Humidity
–
5 to 95% without condensation
Climatic
pressure
–
Climatic pressure: 4000 meters
EMI/ESD
–
CE class B Compliant (EN61326-1)
–
FCC 47-1 Part 15 Compliant
Electrical
Safety
–
EN 61010-1: 2001 Compliant
Drop test
In accordance with the Telcordia GR-196-CORE recommendations, the
2000 Platform resists the following test:
–
6 impacts dropped from a height of 1m on a pinwood floor of 5 cm
thickness (1 impact on each of its 6 sides, with power off).
Shocks
The 2000 Platform resists the following test:
–
3 shocks per axis along each of the 3 axes, with power off.
–
Impacts of 15g, 1/2 sine, duration 11 ms, at 10 second intervals.
Bumps
The 2000 Platform resists the following test:
–
1,000 bumps per axis along each of the 3 axes, with power off.
–
Jolts of 15g, 1/2 sine, duration 6 ms, at 1 second intervals.
–
Operating temperature range
-20°C to +50°C (-4°F to +122°F)
–
Operation including all options
(guaranteed specifications)
0° to +40°C (+32°F to +104°F)
–
Storage
-20
C to +60
C (-4°F to +140°F)
2000 Platform English rev00.book Page 72 Lundi, 20. juin 2011 1:47 13
Содержание 2000 Platform
Страница 3: ...2000 Platform English rev00 book Page ii Lundi 20 juin 2011 1 47 13...
Страница 5: ...2000 Platform English rev00 book Page iv Lundi 20 juin 2011 1 47 13...
Страница 121: ...Index User Manual 790000002 00 102 2000 Platform English rev00 book Page 102 Lundi 20 juin 2011 1 47 13...
Страница 122: ...2000 Platform English rev00 book Page 103 Lundi 20 juin 2011 1 47 13...