FEDERAL PACIFIC PMDF Series Скачать руководство пользователя страница 1

601 Old Airport Road • Bristol, VA 24201   Phone (276) 669-4084 • FAX (276) 669-1869 • www.federalpacific.com • ISO9001:2015

SECTION IB-2D-700

INSTALLATION & OPERATION INSTRUCTIONS

PMDF PAD-MOUNTED SWITCHGEAR 

NOVEMBER 2017 VER. 2.1

PAGE 1

TYPE PMDF 

INSTRUCTIONS FOR INSTALLATION AND OPERATION

15kV • 25kV • 35kV

QUALIFIED PERSONS   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 1
SAFETY    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 2

  Safety Information   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
  Following Safety Instructions  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2
  Safety Precaution  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2

INTRODUCTION   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3

 Receiving   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
 Handling  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
 Storage  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3

GENERAL DESCRIPTION    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3
SECURITY FEATURES   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 3
INSTALLATION   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 4

  Placement of Unit  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
  Customer Cable Connections  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4

BUSHING WELLS AND BUSHINGS    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 5

  Bushing Wells   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5
 Bushings  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6

REMOVAL OF LOADBREAK ELBOWS   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 6
INSTALLATION OF METERING TRANSFORMERS    .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 7
TYPICAL DIMENSIONS  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 8
DOOR SYSTEM  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 9

  Door-Latch Features  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9

MAINTENANCE   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 10
OPTIONAL FEATURES   .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  .  . 10

Figure 1. External views of PMDF Pad-Mounted Switchgear with optional 

KWH meter mounted in an isolated low-voltage compartment attached to unit. 

Federal Pacific PMDF models meet applicable industry standards, which are 

ANSI 386 and IEEE C57.12.28.

© 2014 Electro-Mechanical Corporation

Qualified Persons

The equipment covered by this publication must be selected for a spe-

cific application and it must be operated and maintained by 

Qualified 

Persons

 who are thoroughly trained  and knowledgeable in the instal-

lation, operation, and maintenance of underground power distribution 

equipment along with the associated hazards that may be involved. This 

publication is written only for such qualified persons and is not intended 

to be a substitute for adequate training and experience in safety proce-

dures for this type of equipment. Proper installation is the responsibility 

of the operating and construction personnel and the utility performing 

and authorizing the work. Completion of these instructions implies no 

further warranty by the manufacturer.

Qualified Person

 is defined in the National Electrical Code (NEC/

NFPA-70) as:
One who has skills and knowledge related to the construction and op-

eration of the electrical equipment and installations and has received 

safety training to recognize and avoid the hazards involved.
The specific electrical safety training requirements to be considered a 

qualified person are detailed in 

NFPA-70E, Article 110 .1(D), Employee 

Training

.  Some of the requirements from the 2012 edition are shown 

below.  For the specific detailed training requirements for a Qualified 

Person make certain to refer to the most recent applicable edition.

These training requirements would include, but are not limited, to the 

following key points:
• The skills and techniques necessary to distinguish exposed energized 

parts from other parts of electrical equipment.
• The skills and techniques necessary to determine the proper approach 

distances corresponding to the voltages to which the qualified person 

will be exposed.
• The proper use of the special precautionary techniques, personal pro-

tective equipment, insulating and shielding materials, and insulated tools 

for working on or near exposed energized parts of electrical equipment.
• Tasks performed less often than once per year have additional training 

requirements.
These instructions are intended only for such qualified persons. They 

are not intended to be a substitute for adequate training and experience 

in safety procedures for this type of equipment. Additionally, the recom-

mendations in this instruction bulletin are not intended to supersede or 

to take the place of established utility safety guidelines and established 

practices. If there is any question, consult with your foreman or supervi-

sor, as appropriate.
Please refer to OSHA 29 CFR 1910.399 and NFPA 70E Articles 100 and 110.

WARNING

 

Содержание PMDF Series

Страница 1: ...utility performing and authorizing the work Completion of these instructions implies no further warranty by the manufacturer A Qualified Person is defined in the National Electrical Code NEC NFPA 70 as One who has skills and knowledge related to the construction and op eration of the electrical equipment and installations and has received safety training to recognize and avoid the hazards involved...

Страница 2: ...ent labels are available by contacting Federal Pacific SAFETY PRECAUTION FOLLOWING SAFETY INSTRUCTIONS NOTICE Thoroughly and carefully read this instruction bulletin before installation of the pad mounted switchgear before switching with elbows or installingoraccessingthemeteringtransformers in this equipment and before performing any maintenance on the equipment DANGER Federal Pacific Fuse Mounti...

Страница 3: ...nish the protective film must be removed for outdoor storage of unit Export or special packing is available as an option based on customer s requirements and special conditions Separate in structions are available for these situations Figure 2 Lifting Method General Description PMDF dead front pad mounted switchgearconsistsofoneormore single pole 200 ampere bushing wells to accommodate 200 ampere ...

Страница 4: ...plied between unit base and pad to prevent entry of foreign objects vegetation insects animals and moisture Figure 3 Typical pad layout and associated circuit diagram for one particular PMDF design DO NOT USE FOR CONSTRUCTION PURPOSES 2 Connect the concentric neutral wires to the enclosure ground padsinsidetheenclosuretofacilitategroundsystemconforming to user s grounding procedures The maximum mo...

Страница 5: ... requirements Bushing Wells The 200 ampere bushing wells accommodate 200 ampere elbow separableinsulated loadbreakconnectorsandaccessories The unitsareshippedwithayellowdustcoverovereachbushingwell topreventcontamination DustcoversareNOTcapableofprovid inganyelectricalinsulationatmediumvoltagelevels Therefore if an elbow is not to be connected to a bushing well prior to energization the dust cover...

Страница 6: ...reak Elbows 1 Removethepadlockandfullyloosenthepenta headbolt Pull and lower the door handle cover to open the active elbow compartmentdoorandsecurewiththewindbrace SeeFigures 7 through 14 2 Loosenthetwopentaheadboltsthatsecurethepassiveelbow compartment door and secure it open using the windbrace 3 System operating practices may allow loadbreak elbows to be switched while the associated cable is ...

Страница 7: ...lation of Metering Transformers 1 Removethepadlockandfullyloosenthepenta headbolt Pull and lower the door handle cover to open the active elbow compartmentdoorandsecurewiththewindbrace SeeFigures 7 through 14 2 Loosenthetwopentaheadboltsthatsecurethepassiveelbow compartment door and secure it open using the windbrace 3 Loosenthepenta headboltsoneachinnerbarrierandsecure them open using the pin pro...

Страница 8: ... 315 R6 200 15 95 54 54 51 22 28 14 14 7 NA NA 22 62 62 46 46 PMDF 315 L9 200 15 95 54 54 51 22 28 14 14 7 5 8 5 8 22 62 62 46 46 PMDF 325 R6 200 25 125 66 66 51 24 1 2 30 1 2 17 1 2 16 8 1 2 NA NA 24 74 74 58 58 PMDF 325 L9 200 25 125 66 66 51 24 1 2 30 1 2 17 1 2 16 8 1 2 6 8 3 8 24 74 74 58 58 PMDF 335 R6 200 35 150 76 66 53 24 1 2 33 22 1 2 18 5 16 12 9 16 5 5 8 8 1 2 24 74 84 68 58 34 5 kV de...

Страница 9: ...oor handle See Figures 8 through 10 Figure 13 Padlock cannot be inserted until penta head bolt is fully tightened Figure 14 Always close latch and padlock the enclosure door before leaving the unit or when working on the opposite side Figure 10 Door handle cover is secured closed by a penta head or hex head bolt Turn socket counter clockwise to loosen bolt Figure 9 Door handle is stainless steel F...

Страница 10: ...sformer compartment of the switchgear 2 Checkforcleanlinessgenerally butparticularlyforaccumula tionofanyforeignmaterialoninsulators barriersandmetering transformers Barriersandinsulatorscanbecleanedwithanon alcoholbased cleaner that does not leave any residue when dry Residue must be removed Optional Features Standard options can be supplied that best serve the customer s needs and operating prac...

Страница 11: ...l VA 24201 Phone 276 669 4084 FAX 276 669 1869 www federalpacific com ISO9001 2015 SECTION IB 2D 700 INSTALLATION OPERATION INSTRUCTIONS PMDF PAD MOUNTED SWITCHGEAR NOVEMBER 2017 VER 2 1 PAGE 11 This Page Intentionally Left Blank ...

Страница 12: ...PAD MOUNTED SWITCHGEAR NOVEMBER 2017 VER 2 1 PAGE 12 This Page Intentionally Left Blank Every effort is made to ensure that customers receive an up to date instruction manual on the use of Federal Pacific products however fromtimetotime modificationstoourproductsmaywithoutnoticemaketheinformationcontained herein subject to alteration 2014 Electro Mechanical Corporation ...

Отзывы: