 Series Banknote Acceptor (EBA-40) Integration Guide

Insertion Slot to direct Sunlight or incandescent 

light.

5.  Do not allow the Acceptor to endure a range of 

temperature and humidity beyond the environ-

mental limits specified (See “Environmental 

Specifications” on page 7 of this Section).

6.  Do not use the Acceptor in environments that 

may be subject to server temperature changes.

7.  Do not use the Acceptor where it may be exposed 

to airborne evaporated or sporadic chemicals.

8.  Clean and maintain the Acceptor regularly when 

located in an excessively smoke filled environ-

ment.

Mounting, Dismounting & Transportation

Methods for mounting, dismounting and transport-

ing the unit:

1.  Be sure to turn the Power OFF before mounting 

or removing the Unit from its permanent location. 

Plugging or unplugging Connector Plugs from 

their receptacles while the Power is ON may 

cause damage to the Unit.

2. When 

reassembling 

disassembled Unit Part, 

ensure that the each part is properly replaced in its 

correct original location and the Acceptor is not 

removed by pulling it forward.

3.  Be sure to carry the Unit by both hands when 

transporting it. Holding the Unit by one hand may 

cause personal injury if the Unit accidentally 

becomes disassembled and drops away.

4.  Be careful not to use excessive outside pressure 

on the Unit, or subject it to excessive vibration 

during transportation.

Placing Foreign Objects into the Unit

Observe the following precautions when placing 

foreign objects into the Unit:

1.  Do not insert anything except Banknotes into the 

Insertion Slot. Inserting Receipts, Stapled Tickets, 

Rubber Bands, or Credit Cards into the Unit may 

damage the Banknote Transport path.

2.  Do not inject liquids into the Banknote Insertion 

Slot. Injecting water, oil or cleaning agents may 

damage the Sensors within the Banknote Trans-

port path.

Preventive Maintenance

The preventive maintenance requirements are 

defined as follows:

1.  When closing the Upper Tray of the Acceptor, 

ensure that it clicks firmly into place.

 

 

2.  Do not redesign or disassemble the EBA-40 

Acceptor. Unauthorized use by inadequately 

trained personnel, or use outside the original man-

ufacturer’s intent for operation voids the war-

ranty.

3. Perform 

routine 

cleaning 

and maintenance at least 

once a month to keep the EBA-40 Unit’s perfor-

mance stable.

4.  Use a soft, lint-free cloth, cotton swab or com-

pressed air spray to clean dust and debris from the 

Rollers.    

5.  If the Unit is exposed to water or liquids, use a 

clean, dry micro-fiber cloth to wipe off and 

absorb excess liquids immediately. Any remain-

ing liquids or fluids may affect and degrade the 

Sensors and Validation component performance. 

Caution: Turn the EBA-40 Unit’s Power 
OFF when opening the Upper Tray; 
otherwise, the Rollers may begin 
operating and personal injury to fingers 
may occur by getting them pulled into 
the Unit.

Caution: Be careful to avoid personal 
injury to your fingers when closing the 
Upper Guide Section.

WARNING: Do not inject water or liquid 
agents of any kind into the Acceptor, as 
this may cause extreme damage to the 
Unit.

WARNING: To minimize risk of damage 
to internal printed circuit boards, never 
allow excess fluid (e.g., from a wet 
cleaning cloth) to drip or leak into the 
device. Internal printed circuit boards 
may be damaged. Do not use any 
alcohol, citrus based cleaners, solvents 
or scouring agents that can damage the 
plastic surfaces of the device.

Caution: Make sure Interface Harness 
connections to the Host Machine are 
shorter than 9.84 Feet (3 Meters) in 
length. Cut off all unused portions of 
the Interface Harness wiring to avoid 
static electrical effects or short circuit 
possibilities that could cause damage 
to the Unit.

WARNING: This Unit is designed for 
use with a Current limiting Power 
Source! Design the Host Cabinet space 
to meet all local related safety 
standards.

Содержание EBA-40

Страница 1: ...O LTD Support http www jcmglobal com en contact default aspx website http www jcmglobal com Issue 4103 IGE 01 00 EBA Series Banknote Acceptor EBA 40 Integration Guide Revision A December 4 2013 P N 96...

Страница 2: ...anual to maintain operation of the product or operate the product in general JCM retains all rights to amend alter change or delete any portion of this Manual in whole or in part or add items thereto...

Страница 3: ...ion 8 Acceptor Head Installation 8 Lock Installation 9 DIP Switch Configurations 10 4 CONNECTOR PIN ASSIGNMENTS 11 CONNECTOR PIN ASSIGNMENTS Continued 1 12 CONNECTOR PIN ASSIGNMENTS Continued 2 13 CON...

Страница 4: ...ons 28 LED Flash Reject Code Conditions Banknotes 30 LED Reject Error Code Conditions Barcode Coupons 31 9 UNIT DIMENSIONS 33 Entire Unit Outside Dimensions 33 Head Assembly Outside Dimensions 33 10 T...

Страница 5: ...etrieving Banknotes 18 Figure 15 Clearing an Entrance Banknote Jam 18 Figure 16 Clearing a Stacker Box Banknote Jam 18 Figure 17 Sensor Cleaning 19 Figure 18 EBA 40 Sensor and Roller Cleaning Location...

Страница 6: ...THIS PAGE INTENTIONALLY LEFT BLANK EBA Series Banknote Acceptor EBA 40 Integration Guide P N 960 000173R_Rev A EDP 229278 2013 JAPAN CASH MACHINE CO LTD iv...

Страница 7: ...nments 11 Table 11 EBA 40 MDB Interface Pin Assignments 12 Table 12 EBA 40 ccTalk Interface Pin Assignments 13 Table 13 EBA 40 Photo Coupler Interface Pin Assignments 14 Table 14 EBA 40 RS232C Interfa...

Страница 8: ...THIS PAGE INTENTIONALLY LEFT BLANK EBA Series Banknote Acceptor EBA 40 Integration Guide P N 960 000173R_Rev A EDP 229278 2013 JAPAN CASH MACHINE CO LTD vi...

Страница 9: ...nts Preventive Maintenance Standard Interface Circuit Schematics Operational Flowchart Troubleshooting Unit Dimensions International Compliance Technical Contact Information In order to make operating...

Страница 10: ...ot to use excessive outside pressure on the Mounting Plate when removing the Cash Box from the Unit 4 Avoid exposing the Banknote Insertion Slot to direct Sunlight and or Incandescent Lamp illuminatio...

Страница 11: ...amage the Sensors within the Banknote Trans port path Preventive Maintenance The preventive maintenance requirements are defined as follows 1 When closing the Upper Tray of the Acceptor ensure that it...

Страница 12: ...tains the following primary features Proven Anti Pullback Technology This JCM patented Anti Pullback Mechanism provides powerful protection against Banknote stringing Automatic Centering The Centering...

Страница 13: ...tor EBA 40 Integration Guide Component Names Figure 6 illustrates the EBA 40 component names and locations Figure 6 EBA 40 Component Names a Acceptor Unit b DIP Switch Block 2 c DIP Switch Block 1 d C...

Страница 14: ...re details Standard Specification Read code interleaved 2 of 5 Narrow Bar 0 5 0 6mm 0 019 0 023 in Wide Bar to Narrow Bar ratio 3 1 Characters 18 Characters Print Position Middle Divides a Coupon equa...

Страница 15: ...incandescent with a Radiant Angle of 15 Degrees or more having an Illumination index of 3000 Lux or less Installation Indoors Only Table 6 EBA 40 Electrical Specifications Supply Voltage 12V DC 5 Gre...

Страница 16: ...of the Frame when this mounting configuration is preferred See Figure 8 ACCEPTOR HEAD INSTALLATION Perform the following steps to install the EBA 40 Acceptor Head Assembly using the Mounting Bracket...

Страница 17: ...ed Lock Installation One security lock can be installed onto the EBA 40 SD3 Stacker When installing a security lock the following attachment accessories may be required Tang Choose a Lock that fits a...

Страница 18: ...y characteristics Figure 13 Key Unlock Rotation Requirement Unlock Table 8 DIP Switch Block 1 Settings Switch No Switch ON Switch OFF 1 VEND 1 INHIBIT VEND 1 ACCEPT 2 VEND 2 INHIBIT VEND 2 ACCEPT 3 VE...

Страница 19: ...Housing XG4M 1630 T Flat Cable OMRON Recommended Wire UL2651 AWG 28 Pin No Signal Name I O I O input output is the terminal as viewed from the Banknote Acceptor s backside Function 1 12V 24V Power Sup...

Страница 20: ...RON Recommended Wire UL2651 AWG 28 Pin No Signal Name I O I O input output is the terminal as viewed from the Banknote Acceptor s backside Function 1 12V 24V Power Supply 2 GND GND 3 12V 24V Power Sup...

Страница 21: ...T Flat Cable OMRON Recommended Wire UL2651 AWG 28 Pin No Signal Name I O I O input output is the terminal as viewed from the Banknote Acceptor s backside Function 1 12V 24V Power Supply 2 GND GND 3 12...

Страница 22: ...G 28 Pin No Signal Name I O I O input output is the terminal as viewed from the Banknote Acceptor s backside Function 1 12V 24V Power Supply 2 GND GND 3 12V 24V Power Supply 4 GND GND 5 TTL TXD OUT No...

Страница 23: ...ewed from the Banknote Acceptor s backside Function 1 12V 24V Power Supply 2 GND GND 3 12V 24V Power Supply 4 GND GND 5 TTL TXD OUT No Connection 6 SG No Connection 7 TTL RXD IN No Connection 8 ccTalk...

Страница 24: ...g XG4M 1630 T Flat Cable OMRON Recommended Wire UL2651 AWG 28 Pin No Signal Name I O I O input output is the terminal as viewed from the Banknote Acceptor s backside Function 1 12V 24V Power Supply 2...

Страница 25: ...No Signal Name I O Function 1 Vbus USB Communication Vbus Signal Line 2 D USB Communication Input Output Signal Line 3 D IN OUT USB Communication Input Output Signal Line 4 IN OUT No Connection 5 USB...

Страница 26: ...tly rub the Sensors and Rollers clean using a dry soft lint free Micro fiber Cloth ONLY Do not use any Alcohol solvents Citrus based products or scouring agents that may cause damage to the Validation...

Страница 27: ...ble 19 EBA 40 Sensor Type Cleaning Methods Sym Sensor Roller Type Sym Sensor Roller Type Cleaning Method a Entrance Sensor e Barcode Sensor Option Wipe clean using a soft lint free cloth or blow clean...

Страница 28: ...e 6 STANDARD INTERFACE CIRCUIT SCHEMATICS Figure 19 illustrates the EBA 40 TTL Interface Schematic Diagram Figure 20 illustrates the EBA 40 MDB Interface Schematic Diagram CONTROLLER SIDE EBA SIDE Fig...

Страница 29: ...CE CIRCUIT SCHEMATICS Continued 1 Figure 21 illustrates the EBA 40 ccTalk Interface Schematic Diagram Figure 22 illustrates the EBA 40 Photo Coupler Interface Schematic Diagram CONTROLLER SIDE EBA SID...

Страница 30: ...RD INTERFACE CIRCUIT SCHEMATICS Continued 2 Figure 23 illustrates the EBA 40 RS232C Interface Schematic Diagram Figure 24 illustrates the EBA 40 USB Interface Schematic Diagram CONTROLLER SIDE EBA SID...

Страница 31: ...TD 2 3 EBA Series Banknote Acceptor EBA 40 Integration Guide STANDARD INTERFACE CIRCUIT SCHEMATICS Continued 3 Figure 25 illustrates the EBA 40 Bezel LED Interface Schematic Diagram CONTROLLER SIDE EB...

Страница 32: ...ng c Stand by d Enable Acceptance f External LED Display shows Enable Accept Pattern g Inserted the Banknote h Intake the Banknote i Centering the Banknote j Start Transporting the Banknote k Sampling...

Страница 33: ...ow See Figure 26 c Denomination Signal Output g Is the Banknote transported to Stacker D To f function on this chart f Transporting the Banknote B To Stacking Flow See Figure 28 1 When an abnormal sig...

Страница 34: ...ired to correct them 8 TROUBLESHOOTING Table 20 General Fault Conditions Symptoms Error Messages Possible Fault Causes Corrective Action Required Banknote Acceptor is not working does not accept any B...

Страница 35: ...EBA Sensors following reassembly Motor continues to run Upper Guide is open Firmly close the Upper Guide A foreign object or a jammed Banknote is stuck in the Transport path Open the Upper Guide remo...

Страница 36: ...ROM Boot I F Area ROM Check Error The Boot Interface Area was not written correctly or cannot be read Solution Re download the Program If the error is not resolved check that the following part is as...

Страница 37: ...than specified value for the function Solution Check that the following parts are properly assembled and or Harness connected Clean or adjust the following parts and Sensors Relative Parts Entrance Se...

Страница 38: ...Solutions OFF Green 1 Skewed Insertion Error The Banknote has been inserted in an incorrect crooked direction Solution Insert a Banknote in the proper direction If the error is not resolved insert a...

Страница 39: ...e Banknote is not damaged nor exhibiting unfit conditions Refer to Banknote Fitness Requirements on page 4 for unacceptable Banknote types Relative Parts Validation Sensor If the error is not resolved...

Страница 40: ...normal Barcode Coupon magnification condition Solution Check that a proper Barcode Coupon is used and the Ticket is not damaged or exhibiting unfit conditions as shown on page 4 Check that the followi...

Страница 41: ...9 illustrates the EBA 40 Unit s outside dimensions with the SD3 Stacker HEAD ASSEMBLY OUTSIDE DIMENSIONS Figure 30 illustrates the EBA 40 Head Assembly s outside dimensions without the SD3 Stacker NOT...

Страница 42: ...0 837 7834 Unit B Third Avenue Denbigh West Business Park Bletchley Milton Keynes Buckinghamshire MK1 1DH UK E mail support jcmglobal eu ASIA AND OCEANIA JCM Gold HK Ltd Phone 852 2429 7187 Fax 852 29...

Страница 43: ...rt Operational symbol language describing flow functions 24 I Installation steps required for 8 M Model Descriptions Product Number Specifications of 2 N Navigation within manual procedure for 1 P Pin...

Страница 44: ...P N 960 000173R_Rev A EDP 229278 2013 JAPAN CASH MACHINE CO LTD 3 6 EBA Series Banknote Acceptor EBA 40 Integration Guide THIS PAGE INTENTIONALLY LEFT BLANK...

Страница 45: ...P N 960 000173R_Rev A EDP 229278 2013 JAPAN CASH MACHINE CO LTD 3 7 EBA Series Banknote Acceptor EBA 40 Integration Guide...

Страница 46: ...P N 960 000173R_Rev A EDP 229278 2013 JAPAN CASH MACHINE CO LTD EBA Series Banknote Acceptor EBA 40 Integration Guide Issue 4103 IGE 01 00...

Отзывы: