P/N 960-000173R_Rev. A {EDP #229278}
© 2013, JAPAN CASH MACHINE CO., LTD.
3
Series Banknote Acceptor (EBA-40) Integration Guide
Insertion Slot to direct Sunlight or incandescent
light.
5. Do not allow the Acceptor to endure a range of
temperature and humidity beyond the environ-
mental limits specified (See “Environmental
Specifications” on page 7 of this Section).
6. Do not use the Acceptor in environments that
may be subject to server temperature changes.
7. Do not use the Acceptor where it may be exposed
to airborne evaporated or sporadic chemicals.
8. Clean and maintain the Acceptor regularly when
located in an excessively smoke filled environ-
ment.
Mounting, Dismounting & Transportation
Methods for mounting, dismounting and transport-
ing the unit:
1. Be sure to turn the Power OFF before mounting
or removing the Unit from its permanent location.
Plugging or unplugging Connector Plugs from
their receptacles while the Power is ON may
cause damage to the Unit.
2. When
reassembling
a
disassembled Unit Part,
ensure that the each part is properly replaced in its
correct original location and the Acceptor is not
removed by pulling it forward.
3. Be sure to carry the Unit by both hands when
transporting it. Holding the Unit by one hand may
cause personal injury if the Unit accidentally
becomes disassembled and drops away.
4. Be careful not to use excessive outside pressure
on the Unit, or subject it to excessive vibration
during transportation.
Placing Foreign Objects into the Unit
Observe the following precautions when placing
foreign objects into the Unit:
1. Do not insert anything except Banknotes into the
Insertion Slot. Inserting Receipts, Stapled Tickets,
Rubber Bands, or Credit Cards into the Unit may
damage the Banknote Transport path.
2. Do not inject liquids into the Banknote Insertion
Slot. Injecting water, oil or cleaning agents may
damage the Sensors within the Banknote Trans-
port path.
Preventive Maintenance
The preventive maintenance requirements are
defined as follows:
1. When closing the Upper Tray of the Acceptor,
ensure that it clicks firmly into place.
2. Do not redesign or disassemble the EBA-40
Acceptor. Unauthorized use by inadequately
trained personnel, or use outside the original man-
ufacturer’s intent for operation voids the war-
ranty.
3. Perform
routine
cleaning
and maintenance at least
once a month to keep the EBA-40 Unit’s perfor-
mance stable.
4. Use a soft, lint-free cloth, cotton swab or com-
pressed air spray to clean dust and debris from the
Rollers.
5. If the Unit is exposed to water or liquids, use a
clean, dry micro-fiber cloth to wipe off and
absorb excess liquids immediately. Any remain-
ing liquids or fluids may affect and degrade the
Sensors and Validation component performance.
Caution: Turn the EBA-40 Unit’s Power
OFF when opening the Upper Tray;
otherwise, the Rollers may begin
operating and personal injury to fingers
may occur by getting them pulled into
the Unit.
Caution: Be careful to avoid personal
injury to your fingers when closing the
Upper Guide Section.
WARNING: Do not inject water or liquid
agents of any kind into the Acceptor, as
this may cause extreme damage to the
Unit.
WARNING: To minimize risk of damage
to internal printed circuit boards, never
allow excess fluid (e.g., from a wet
cleaning cloth) to drip or leak into the
device. Internal printed circuit boards
may be damaged. Do not use any
alcohol, citrus based cleaners, solvents
or scouring agents that can damage the
plastic surfaces of the device.
Caution: Make sure Interface Harness
connections to the Host Machine are
shorter than 9.84 Feet (3 Meters) in
length. Cut off all unused portions of
the Interface Harness wiring to avoid
static electrical effects or short circuit
possibilities that could cause damage
to the Unit.
WARNING: This Unit is designed for
use with a Current limiting Power
Source! Design the Host Cabinet space
to meet all local related safety
standards.