 Operation Manual 

】 

 
 
 

 

Batch  counter  

 
 

 MODEL:CU-675 Series  

 
 
 
 
 
 
 
 

Series 

name

 

Communi

cation 

Input 

Signal 

Sensor 

Voltage 

Function

 

CU-675 

 

 

 

 ・

NPN open collector Pulse

/Voltage Pulse input 

 ・AC85~264V free power 
 ・DIN W72×H144×D122 mm 

 

RS2 

 

 

 RS-232C Communication 

RS4 

 

 

 RS-485 Communication(2-Wire) 

RS4W 

 

 

 RS-485 Communication(4-Wire) 

 

 

A2 

 

 Analog current input(DC4~20mA)For deviation 

detection 

 

 

Standard  Sensor Power DC12V 100mA Below 

 

S24   Sensor Power DC24V  60mA Below 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

【 4th edition 13th January 2016 】 

                                                                           @CU-675(4)-E 

Содержание CU-675 Series

Страница 1: ...Pulse Voltage Pulse input AC85 264V free power DIN W72 H144 D122 mm RS2 RS 232C Communication RS4 RS 485 Communication Wire RS4W RS 485 Communication Wire A2 Analog current input DC4 20mA For deviati...

Страница 2: ...is avoided and ratings are used in the place of each Onshime and the place where the be dewy occurs easily Do not do Caution Do not use it in the place with the combustible gas and the ignition thing...

Страница 3: ...value 23 Mode No 04 Setting of termination signal of output timing and output width 24 Mode No 05 Current display position correction setting of the measurement operation 25 Mode No 06 Setting of inp...

Страница 4: ...case that you don t attach by convenience About a guaranteed period and a guaranteed area Guaranteed period The period a product guarantees is 4 years from a delivered day Guaranteed area If we troubl...

Страница 5: ...lays 1 3 decimal points selectable PV display reset Use the start key or start signal for reset start of surveying from 0 Selection when reset start Keep reset key is ON for more than two seconds Term...

Страница 6: ...put Termination signal display END lamp lighting Output method Relay 1a Contact output AC250V DC30V 3A MAX Resistance load Signal input anomaly detection Abnormal measurement Abnormal deviation Output...

Страница 7: ...and lower limit 0 to 9999 Scaling converter At analog MAX value arbitrarily set in 0 001 to 9999 Communication Option RS2 RS4 RS4W Type Table 3 Signal level RS2 EIA RS 232 standard RS4 W EIA RS 485 s...

Страница 8: ...ed ON outputs the control signal Please note that a deceleration signal is not output 2 The start key the start signal is turned OFF releases the control signal Please note that termination signal is...

Страница 9: ...Slide in the rear side terminal stand side as for the fitting for fixing the body It turns a screw by the driver The meter is fixed right and left both sides Fig 3 When installing the meter 1 Please...

Страница 10: ...t release too It is the same as the reset key on the front panel Please connect to the terminal block 3 4 Note Reset in the batch control will can not be a successful batch control Stop signal When th...

Страница 11: ...value Abnormal signal When the abnormal signal was input measurement abnormal signal is output the measurement abnormal display ALM is lights the batch control stop Deviation Abnormal Option A2 When...

Страница 12: ...firming the terminal stand label 4 The wiring technique is different depending on the kind of the sensor Please refer P 7 Fig 4 to Fig 6 Because the sensor power supply is DC12V 100mA MAX Option DC24V...

Страница 13: ...10 6 Construction of input circuit output circuit Sensor input Fig 7 Signal input Fig 8 Analog input Fig 9 Signal output Fig 10...

Страница 14: ...ble 4 SW set NPN open collector input Voltage pulse Input Input frequency less than 50Hz LO Input frequency less than 10kHz HI Set the DIP switch with hole in the side of the case Unless otherwise spe...

Страница 15: ...urement display the PV value Measured value Mode setting Disuplay the date value according to the mode SV diaplay Display measurement Display the Target value SV value CH display Display measurement C...

Страница 16: ...the slowdown signal is output lights End signal display Green When the end signal output lights Normal stop display Green Stop in a normal state lights Manual display Orange When the manual state lig...

Страница 17: ...splay value will be to 0 Mode set Function as up key Set value up by 1 Clear key Automatic mode Pressed for more than 2seconds switched to manual mode Manual Pressed for more than 2seconds switched to...

Страница 18: ...15 9 The setting menu Test mode...

Страница 19: ...16 Various setting operations...

Страница 20: ...K L J K L 0 Initialization Throw power supply in with pressed to initialize the settings After the initialization the set values will be as shown in Table 5 Table 6 Mode protect function are also cle...

Страница 21: ...Display SV in A to B Display C to L is Blank SV settings confirmation menu Press return to the search screen Press Display SV value in the display G to L Press Clear the Setting value to zero Please e...

Страница 22: ...etup 1 Whenever it pushes once the mode No goes up Change the blinkig numeral value Whenever it pushes once it moves to the right This key becomes invalid during mode protection Display blink is carri...

Страница 23: ...t display decimal point Single below decimal point Double below decimal point Triple below decimal point Set value Numerical setup Keystroke setup Start operation Resetstart measurement start from 0 N...

Страница 24: ...l box reset signal Set value 0 Numerical setup It is made to operate by a numerical value is put into SV value 1 CH setup From CH data which has registered SV value a preset value is chosen and is ope...

Страница 25: ...set up to the 3rd place It sets to a decimal point by a Shift key and moves a decimal point by a rise key overrun correction value 00 000 99999 overrun correction value When a measurement value reach...

Страница 26: ...witching action It is operation in case the flow velocity is controlled by two step opening and closing by a valve etc It outputs to a part for the value set up from the start time and outputs to the...

Страница 27: ...a control signal is canceled Output width The output width time t2 of an end signal is set up When output maintenance 0 0 is set up it cancels by start signal or switch ON Output timing Output width T...

Страница 28: ...TAL display and PV display also measures a flow Mode No Setting of input anomaly detection The number of anomaly detection pulses 01 99 00 is functional stop Anomaly detection time 00 1 19 9 sec 00 0...

Страница 29: ...the magnification per 1 pulse For example Display of addition flow by L min in the use of flow sensor of 1 234mL per 1 pulse Converted to theintended value L todisplay Converter value H K 1234 Convert...

Страница 30: ...ndicated value in the analog input MIN is being fixed to 0 Mode No Setting of deviation error analog input setting of output of upper and lower limit decision prohibit time use of decision prohibit ti...

Страница 31: ...sed by setup of upper limit Fig 18 Release of an abnomal output If reset is turned on a measurement abnomal signal will be canceled decision prohibit time After power activation or after reset ON OFF...

Страница 32: ...normalities in a deviation of an analog input is set up Mode No Setting of communication RS2 type RS4 type RS4W type Parity bit 0 None 1 Odd 2 Even Data bit 0 7 bit 1 8 bit Baud rate 0 2400 bps 1 4800...

Страница 33: ...tect state Present It pushes 2 seconds or more in the state of a measurement display Current mode protect state is displayed It is OFF at the time of shipment Mode protect state Change Keeps pushing t...

Страница 34: ...lank and becomes a CH setting check menu If the is pushed it will return to a measurement screen is pushed CH 0 is displayed on A D and Channel preset value is displayed on G L 9 Whenever it pushes on...

Страница 35: ...ta A decimal point is interlocked with the decimal point of a measurement value Preset value Target value 0 999999 The value set up here is used as a desired value by channel operational mode A total...

Страница 36: ...total setting check menu If the is pushed it will return to a measurement screen Is pushed The present total value is displayed on L Is pushed A preset value is cleared A preset value is inputted with...

Страница 37: ...sh on this key will display the analog input minimum set value bit value registered now If this key is pressed inputting the analog minimum input the input value bit value in that time will be registe...

Страница 38: ...S 232C conformity Signal level RS 485 conformity Correspondence procedure Half duplex communication method baud rate It is a mode setup Reference mode 13 bps bps bps bps Start bit 1 bit fixation Stop...

Страница 39: ...notation of the HEX value by MO D Example In the case of CR The indicated value demand of the ID number 01 A commsnd is transposed to an ASCII code hexadecimal number and is added 40H 30H 31H 52H 44H...

Страница 40: ...ue lead Command format CR Response format CR Deviation error analo g input lower limit va lue lead Command format CR Response format CR SV value write 1 Command format CR Response format CR Deviation...

Страница 41: ...38 7 8 9 4 5 6 1 2 3 0 SV CH TOTAL P V S V CH 8 External dimensions External dimensions Fig Panel cut dimensions Unit mm...

Страница 42: ...ease separate from the noise source shorten wiring as much as possible and give the treatment such as EMI filters 4 Wiring technique of sensor code Around the sensor code there are an electric power l...

Страница 43: ...mode R efer to page 15 Initialize Refer to page 17 When it still does not resume normal status have it serviced Rate meter remains at 0 and does not count Is the setting for each mode correct Is the...

Страница 44: ...Head Office 123 1 Kami Nishi ku Sakai city Osaka Japan TEL 81 72 274 6001 FAX 81 72 274 6005 Tokyo Branch TEL 81 3 5256 8311 FAX 81 3 5256 8312...