P/N 960-000173R_Rev. A {EDP #229278}
© 2013, JAPAN CASH MACHINE CO., LTD.
7
Series Banknote Acceptor (EBA-40) Integration Guide
Environmental Specifications
Electrical Specifications
Structural Specifications
Table 5
EBA-40 Environmental Specifications
Operating Temperature:
5ºC to +50ºC (41ºF to 122ºF)
*
*. Depends on hydrothermal conditions.
Storage Temperature:
-20ºC to +60ºC (-4ºF to 140ºF)
*
Relative Operating Humidity:
30% to 85% RH (non-condensed)
Relative Storage Humidity:
30% to 85% RH (non-condensed)
Visible Light Sensitivity:
Avoid contact with direct sunlight
(Interior lighting must be incandescent with a
Radiant Angle of 15 Degrees or more having an Illumination index of 3000 Lux or less)
Installation:
Indoors Only
Table 6
EBA-40 Electrical Specifications
Supply Voltage:
12V DC ±5% (Greater than 3A)
24V DC ±5% (Greater than 1.6A)
*
*. Use a Current Source Limiting Power Supply
Current Consumption:
12V DC
•
Standby = 180mA
•
Operation = 1.0A
•
Peak = 3.0A
24V DC
•
Standby = 110mA
•
Operation = 0.6A
•
Peak = 1.6A
Table 7
EBA-40 Structural Specifications
Weight:
With the SD3 Stacker: Approximately 2.5kg (5.51lbs.)
Without the SD3 Stacker: Approximately 1kg (2.2lbs.)
Mounting:
Horizontal
Outside Dimensions:
See “Entire Unit Outside Dimensions” on page 33 of this Manual
Hydrothermal Condition Table
H
umidity [%RH]
Temperature [ºC]
Allowable
and Humidity Range
Operating
Temperature
50ºC/40RH%
35ºC/80RH%