background image

 

22 

  

 

Varyscan

®

 4 1200 HMI 

 

R24 

150R 

0,6W 

R64 

150R 

0,6W 

R25 

37R 

0,6W 

R65 

75R 

0,6W 

R26 

75R 

0,6W 

R66 

37R 

0,6W 

R27 

300R 

0,6W 

R28 

150R 

0,6W 

R29 

2R 

1W 

R30 

2R 

1W 

R31 

750R 

0,6W 

R32 

250R 

0,6W 

R33 

1,2R 

1W 

R34 

1,2R 

1W 

R35 

1,5R 

1W 

R36 

1,5R 

1W 

R37 

1,2R 

1W 

R38 

1,2R 

1W 

R39 

1,2R 

1W 

R40 

1,2R 

1W 

C1 

18pF 

 

C41 

220nF 

C2 

18pF 

 

C42 

2,2nF 

C3 

4,7uF 

 

C43 

220uF 

C4 

100nF 

 

C44 

220nF 

C5 

100nF 

 

C45 

2,2nF 

C6 

100nF 

 

C46 

100nF 

C7 

22uF 

 

C47 

470uF 

C8 

100n 

 

C48 

100nF 

C9 

100nF 

 

C49 

47uF 

C10 

820pF 

 

C50 

220nF 

C11 

820pF 

 

C51 

47uF 

C12 

47uF 

 

C52 

220nF 

C13 

220nF 

 

C53 

47uF 

C14 

220nF 

 

C54 

220nF 

C15 

47uF 

 

C55 

4700uF 

C16 

220nF 

 

C56 

4700uF 

C17 

220nF 

 

C57 

4700uF 

C18 

100nF 

 

C58 

47uF 

C19 

3,3nF 

 

C59 

220nF 

C20 

220nF 

 

C60 

2,2nf 

C21 

47uF 

 

C61 

47uF 

C22 

220nF 

 

C62 

220nF 

C23 

47uF 

 

C63 

47uF 

C24 

820pF 

 

C64 

220nF 

C25 

820pF 

 

C65 

47uF 

C26 

3,3nF 

 

C66 

220nF 

C27 

no.(not occupied) 

 

C67 

2,2nF 

C28 

220nF 

 

C68 

100nF 

C29 

2,2nF 

 

C69 

4,7uF 

C30 

47uF 

 

C70 

100nF 

C31 

220nF 

C32 

47uF 

C33 

220nF 

C34 

no. 

C35 

220nF 

C36 

2,2nF

 

Содержание Varyscan 4 1200 HMI

Страница 1: ...JB lighting Lichtanlagentechnik GmbH Sallersteigweg 15 D 89134 Blaustein Wippingen Telefon 49 0 7304 9617 0 Telefax 49 0 7304 9617 99 http www jb lighting de english Bedienungsanleitung User Manual...

Страница 2: ...f DIP switch positions for defined DMX addresses 9 Changing of gobos 10 GOBO measurements 10 B Service instructions 11 Adjustment of the mirror stop 11 Adjustment of the motor brake 11 Regular Mainten...

Страница 3: ...3 Varyscan 4 1200 HMI Illustration of VS 4 1200HMI...

Страница 4: ...ack 2 DMX white 2 DMX white 3 DMX red 3 DMX red 4 free 4 not connected 5 5V green black 5 not connected Unpacking of the Varyscan Equipment The box contains Varyscan 1200 HMI operating instructions Ch...

Страница 5: ...Hang up of Varyscan To scoop the optimal functioning of your Varyscan you should hang up the spots as high as possible 2 Adjustment of Varyscan All spots should hang in the same angle i e the imagine...

Страница 6: ...e the right choice of addresses At DIP switch No 2 you find 4 switches for choosing the following functions Infinitely Variable Colour Changing DIP switch No 2 switch 1 i e the moment this function is...

Страница 7: ...el 5 x axis channel 6 y axis DIP switch position DIP switch No 2 switch 2 off switch 3 on 3 JB lighting 6 channel drive mode channel 1 x motor channel 2 y motor channel 3 gobo channel 4 colour channel...

Страница 8: ...resses as follows The addressing works by a binary numeral system and in 6 channel drive mode it has to follow in six steps Varyscan Nr DMX address Dip switch setting 1 1 2 7 3 13 4 19 5 25 6 31 7 37...

Страница 9: ...73 11 81 12 89 Definition of DIP switch positions for defined DMX addresses Every single DIP switch responds to the above designated figures If you would like to adjust a defined DMX address you have...

Страница 10: ...heel out of their holder and then put in other gobos Take care that the gobo engages exactly with it s slits in the holder If the gobo is put in correctly it moves easily inside the holder Now you can...

Страница 11: ...work Control DIP switch position Adjustment of the mirror stop To adjust the mirror of your Varyscan 1200 HMI proceed as follows Adjust the initialisation mode at DIP switch No 1 DIP switch position s...

Страница 12: ...he optical parts of your Varyscan periodically to restore maximum brightness of the scan After having opened the casing as explained above take out the effect wheel slide in see sketch page 4 and put...

Страница 13: ...essary to determine the number of DMX channels for every appliance The occupation of channels of a scan could be like that for example channel 1 x movement channel 2 y movement channel 3 gobo effect w...

Страница 14: ...072 079 colour 10 DMX 080 087 colour 11 DMX 088 095 colour 12 DMX 096 103 colour 13 DMX 104 111 colour 14 DMX 112 119 colour 15 DMX 120 127 colour wheel rotation speed 1 slow DMX 128 colour wheel rota...

Страница 15: ...is channel 6 Y axis channel 1 iris and gobo rotation iris cl osed gobo first position DMX 0 iris open gobo first posi tion DMX 64 second gobo position DMX 65 third gobo position DMX 66 locked into pos...

Страница 16: ...MX 143 155 gobo 3 white DMX 156 168 gobo 3 artificial light filter DMX 169 181 gobo 3 daylight filter DMX 182 194 gobo 3 prism DMX 195 207 gobo 4 white DMX 208 220 gobo 4 artificial light filter DMX 2...

Страница 17: ...DMX 156 168 gobo 3 artificial light filter DMX 169 181 gobo 3 daylight filter DMX 182 194 gobo 3 prism DMX 195 207 gobo 4 white DMX 208 220 gobo 4 artificial light filter DMX 221 233 gobo 4 daylight f...

Страница 18: ...t position DMX 64 second gobo position DMX 65 third gobo position DMX 66 locked into position 360 DMX 191 locked into position 540 DMX 191 rotation left highest speed DMX 192 rotation left lowest spee...

Страница 19: ...ring the electronic board with the plan of electronic parts you can see the Eprom at the right side IC U2 Carefully lift out the used Eprom from the holder and change it for a new one Attention Pay at...

Страница 20: ...20 Varyscan 4 1200 HMI Plan of current circuits for Varyscan 4 1200HMI...

Страница 21: ...ellow P1 DMX In Out 1 green 2 black 3 rot 4 white JP3 List of parts or electronic board of Varyscan 4 1200 HMI R1 10M 0 6W R41 30R 0 6W R2 22K 0 6W R42 60R 0 6W R3 9 10K Sip 0 25W R43 240R 0 6W R4 9 1...

Страница 22: ...45 2 2nF C6 100nF C46 100nF C7 22uF C47 470uF C8 100n C48 100nF C9 100nF C49 47uF C10 820pF C50 220nF C11 820pF C51 47uF C12 47uF C52 220nF C13 220nF C53 47uF C14 220nF C54 220nF C15 47uF C55 4700uF C...

Страница 23: ...23 Varyscan 4 1200 HMI C37 no C38 220nF C39 2 2nF C40 no Q1 Q32 BC337B P1 P2 Connector DB15 JP2 Header5 JP3 JP4 JP5 Header4...

Страница 24: ...er for goborotation U12 74HC574 U13 74HC574 U14 74HC574 U15 TCA3727 driver for iris U16 TCA3727 driver for gobowheel U17 LM317 U18 TCA3727 driver for colour wheel U19 TCA3727 driver for effect wheel U...

Страница 25: ...25 Varyscan 4 1200 HMI Plan of electronic parts for electronic board of Varyscan 4 1200 HMI...

Отзывы: