Put in/ Exchange of the Bulb
Warning
: Before opening pull out mains plug!
Loosen the screws at the lid of your Varyscan
®
with a suitable screw-driver and lift the lid (label Varyscan
®
4
1200 HMI). You can see the bulb holder in the back third of your
Varyscan
®
(see outline page 4). Now detach nuts No.1 and No.2 and
remove the bulb from it's holder. Put the new HMI bulb into the holder
and tighten nuts No.1 and No.2 by hand. The point on the glass of the
bulb should on no account point to the concave mirror, respectively to
the lenses (outline page 4), it should point to the base sheet or to the lid.
Take care that the bulb is tightened in the holder.
Warning
:
Never
touch the glass of bulb of the 1200 HMI bulb itself!
An adjustment of the bulb is not necessary.
Starting the Equipment
1. Hang up of Varyscan
®
To scoop the optimal functioning of your Varyscan
®
, you should hang up the spots as high as possible.
2. Adjustment of Varyscan
®
All spots should hang in the same angle, i.e. the imagined angle between perpendicular and Varyscan
®
should
be the same among all Varyscans
®
3. Cabling of Varyscan
®
Power supply:
A specialist should attach a plug to the open end of the connecting cable, or have the cable connected to 230
volt 50 hertz.
DMX-cabling:
Connect the output of your DMX-controller with the first Varyscan
®
(controller DMX-out; Varyscan
®
DMX-in) with
the aid of a 5pole XLR-cabel. Now establish the connection between the Varyscans
®
with the aid of further
5pole XLR-cables. Make sure that in DMX-out of the last Varyscan
®
there is a resistor (XLR-plug with a resistance
of 100 Ohm between pin 2 and pin 3) plugged into.
4. Adjustment at DIP-switches
At DIP-switch No.1 and No.2 you have the following possibilities of adjustment:
?
initialisation mode
?
test mode
?
infinitely variable colour changing