6
Varyscan
®
4 1200 HMI
?
optional channels of Varyscan
®
?
reset on DMX
?
DMX-address
Initialisation Mode
This mode serves for adjustment and basic initialisation of the Varyscan
®
(carrying-out by producer).
Test Mode
To see the variety of functions of your Varyscan
®
easily, start the test mode by turning switch 3
off
and switch 2
on
at DIP-switch No.2. Now plug in your scanner and you will largely see it's functions
.
Adjustments at DIP-Switch No.2
Before adjusting DMX-addresses, you have to choose a certain drive mode and then make the right choice of
addresses.
At DIP-switch No.2 you find 4 switches for choosing the following functions.
Infinitely Variable Colour Changing:
DIP-switch No.2 switch 1
i.e. the moment this function is turned on, every DMX-factor between 0 and 128 corresponds to an adjustment
of the colour wheel. You can produce not only half colours but 1/3- 2/3 colours or 1/4- 3/4 colours etc. To
choose this function, turn switch 1 at DIP-switch No.2
on
.
Is switch 1 on position
off
, you get only full colours, respectively half colours.
Optional Drive Modes:
DIP-switch No.2 switch 2 and 3
You have 3 DMX-channel formats to your disposal, which are explained precisely in the following text.
1. JB lighting 8 channel drive mode
channel 1
x-axis