W-Hxy
R-Hxy
Write -
Hibernation
Delay + port +
tool
Read -
Hibernation
Delay + port +
tool
Sets the Hibernation Delay Time.
The ‘x’ must be replaced with the number of the
destination port and the “y” with the tool number* in
ACCII, for example “WH12”, for port 1 and tool TR245.
See page 8 for identifier information.
The Data Field contains the delay time to enter into
Hibernation since the Sleep Tool Operating Status is
reached. The Hibernation Delay must be set in steps
of 5 minutes with a range from 0 to 60 minutes.
The Data Field contains the current Hibernation Delay
Time, expressed in minutes.
To disable the Hibernation mode, send “99999”.
The JBC device answers with an “A-Hxy”.
To get the Hibernation Delay Time.
The ‘x’ must be replaced with the number of the
destination port and the “y” with the tool number* in
ACCII, for example “RH12”, for port 1 and tool TR245.
See page 8 for identifier information.
The JBC device answers with an “A-Hxy”.
The Data Field contains the Hibernation Delay Time,
expressed in minutes.
If get answered “99999”, the Hibernation Mode is
disabled.
Code
Description
Details
16