R-FST
R-SVR
Read - Fuse state
Read - Software
version
To get the JBC Device Fuse status.
The JBC device responds with an “A-FST”.
The Data Field contains the JBC Device Fuse status
value according to:
‘0’ - There is no fuse
‘1’ - There is fuse
Warning: Command only available for UCR
stations.
Code
Description
Details
To get the JBC Device Software Version.
The JBC device responds with an “A-SVR”.
The Data Field contains the requested information.
R-DCx
Read - Counter
Dispensed Cycles
+ port
To read the desoldering counter cycles the ‘x’ must
be replaced with the destination port number in
ASCII of the request, for example “RCD3”.
The equipment answers with an “ACDx” as the
control field, in the example “ACD3”.
Data field will contain the requested information.
R-DLx
Read - Counter
Dispensed Cycles
+ port
To read the dispensed length counter the ‘x’ must be
replaced with the destination port number in ASCII of
the request, for example “RDL1”.
The equipment answers with an “ADLx” as the
control field, in the example “ADL1”.
Data field will contain the requested information in
hexadecimal. Units [dmm].
Example:
1000 dmm -> Data field = 0x00000003E8