W-LDx
R-LDx
Write - Lower
Delay
Alarm + port
Read - Lower
Delay
Alarm + port
Sets the delay time to activate the Lower Temperature
Alarm.
The delay time is counted, when the temperature falls
below the “Lower Temperature Alarm” limit; previously
defined with LAx.
Replace the ‘x’ with the number of the destination
port in ASCII, for example “WLD1”.
The Data Field contains the delay time to activate the
“Lower Temperature Alarm”, expressed in seconds
and hundrets of seconds, according to:
Format “ss.cc” in ASCII. “ss” corresponds to the
time in seconds, and “cc” corresponds to the time
in hundredths of a second. Example: “01.60” means
1,6s; “00.10” means 0,1s.
The JBC device responds with an “A-LDx”.
To disable the Hibernation mode, send “99999”.
To get the delay time to activate the Lower
Temperature Alarm.
When the tip temperature falls down the Lower
Temperature Alarm for a longer time than the delay set
in the W-Lax, the Alarm will be set to 10.
Replace the ‘x’ with the number of the destination
port in ASCII, for example “RLD1”.
The Data Field contains the delay time to activate the
“Lower Temperature Alarm”, expressed in seconds
and hundrets of seconds, according to:
Format “ss.cc” in ASCII. “ss” corresponds to the
time in seconds, and “cc” corresponds to the time
in hundredths of a second. Example: “01.60” means
1,6s; “00.10” means 0,1s.
The JBC device responds with an “A-LDx”
“99999” means that the alarm is disabled.
Code
Description
Details
20