R-STx
R-TTx
R-PPx
Code
Description
Details
Read - Select
Temp. + port
Read - Tip
Temp. + port
Read - Port Power +
port
To get the set Working Temperature.
Replace the ‘x’ with the number of the destination port
in ASCII, for example “RST1”.
The JBC device responds with an “A-STx”.
The Data Field contains the current Working
Temperature, expressed in °C , for expamle
“AST100350”.
To get the current Tip Temperuature.
The ‘x’ must be replaced with the number of the
destination port in ACCII (example “RTT1”).
The JBC device respons with an “A-TTx” and the Data
Field contains the current tip temperature expressed in
°C, expamle “ATT100183”.
To get the current power delivered to the tip.
The ‘x’ must be replaced with the number of the
destination port in ACCII (example “RPP1”).
The Data Field contains the delivered power expressed
in ‰, for example “APP100840” for 84%.
The JBC device response with A-PPx.
12