background image

ENGLISH 

 

OPERATION MANUAL 

 

 
JB SYSTEMS

®

 

2/8 

 WMS-100 + WBS-200 

SAFETY INSTRUCTIONS: 

  To prevent fire or shock hazard, do not expose this appliance to rain or moisture.  

  To avoid condensation to be formed inside, allow the unit to adapt to the surrounding temperatures when 

bringing  it  into  a  warm  room  after  transport.  Condense  sometimes  prevents  the  unit  from  working  at  full 
performance or may even cause damages. 

  This unit is for indoor use only.  

 

Don’t place metal objects or spill liquid inside the unit. No objects filled with liquids, such as vases, shall be 
placed  on  this  appliance.  Electric  shock  or malfunction  may  result.  If  a  foreign  object  enters  the  unit,  im-
mediately disconnect the mains power. 

  No naked flame sources, such as lighted candles, should be placed on the appliance. 

  Prevent use in dusty environments and clean the unit regularly. 

  Keep the unit away from children. 

  Inexperienced persons should not operate this device. 

  Maximum save ambient temperature is 40

°C. Don’t use this unit at higher ambient temperatures. 

  Always unplug the unit when it is not used for a longer time or before you start servicing. 

  The electrical installation should be carried out by qualified personal only, according to the regulations for 

electrical and mechanical safety in your country. 

  Check that the available voltage is not higher than the one stated on the rear panel of the unit. 

  The Mains socket inlet shall remain operable for disconnection from the mains. 

  In  order  to  avoid  a  hazard,  the  unit  shall  only  be  used  with  the  AC-adaptor  delivered  with  it.  If  the  AC-

adaptor is damaged, a same model adaptor shall be used only. 

  No user serviceable parts inside. 

  In the event of serious operating problems, stop using the appliance and contact your dealer immediately. 

  Please use the original packing when the device is to be transported. 

  Due to safety reasons it is prohibited to make unauthorized modifications to the unit. 

  Take  out  the  battery  from  transmitter,  if  the  appliance  has  been  not  used  for  a  longer  period.    This  will 

avoid the damage resulting from a defective leaking battery.  

 

FCC STATEMENT 

This device complies with part 15 of the FCC rules.  Operation is subject to the following two conditions: 

  This device may not cause harmful interference  

  This device must accept any interference received, including interference that may cause undesired opera-

tion 

The changes or modifications not expressly approved by the party responsible for compliance could void the 
user’s authority to operate the equipment. 
IMPORTANT NOTE: To comply with the FCC RF exposure compliance requirements, no change to the an-
tenna or the device is permitted. Any change to the antenna or the device could result in the device exceed-
ing the RF exposure requirements and void user’s authority to operate the device. 
 
 

CAUTION

 

CAUTION:

  To  reduce  the  risk  of  electric  shock,  do  not 

remove  the  top  cover.  No  user-serviceable  parts  inside. 
Refer servicing to qualified service personnel only. 

 

The lightning flash with arrowhead symbol within the equilateral triangle is intended to alert the 
use  or  the  presence  of  un-

insulated  “dangerous  voltage”  within  the  product’s  enclosure  that 

may be of sufficient magnitude to constitute a risk of electric shock. 

 

The exclamation point within the equilateral triangle is intended to alert the user to the presence 
of  important  operation  and  maintenance  (servicing)  instructions  in  the  literature  accompanying 
this appliance. 

 

This symbol means: indoor use only

 

 

This symbol means: Read instructions

 

 

This symbol means: Safety Class II appliance 

Содержание WBS-200

Страница 1: ...Other languages can be downloaded from WWW JB SYSTEMS EU ENGLISH Operation Manual Version 1 0 WBS 200 Wireless Belt Pack System PWR AF A DIVERSITY B PWR AF A DIVERSITY B WMS 100 Wireless Handmic System ...

Страница 2: ......

Страница 3: ... for easy rack mounting Optional RP WMIC 19 adapter available for rack mounting of 1 or 2 receivers Balanced XLR and unbalanced jack output Frequency range 823 832 863 865MHz free use in most European countries BEFORE USE Before you start using this unit please check if there s no transportation damage Should there be any do not use the device and consult your dealer first Important This device le...

Страница 4: ...us operating problems stop using the appliance and contact your dealer immediately Please use the original packing when the device is to be transported Due to safety reasons it is prohibited to make unauthorized modifications to the unit Take out the battery from transmitter if the appliance has been not used for a longer period This will avoid the damage resulting from a defective leaking battery...

Страница 5: ...nals of the are too weak With the squelch control you can determine the minimum RF signal level before audio output is not suppressed anymore Setting the squelch too high will reduce the range max distance of the system The squelch is already set in the factory so normally you don t need to change it If you should adapt the squelch level for any reason please set it to minimum before turning the r...

Страница 6: ... avoid signal overload distortion 8 Lavalier Microphone unidirectional condenser type this dis cretely worn mic can be used to amplify all kinds of sounds ex enhance the voice of a teacher or speaker This lavalier microphone can be replaced by our HM 36U headset micro phone order code 427 often used for aerobics etc 9 Tie Clip used to clip the lavalier on the tie or lapel of a person 10 Battery Co...

Страница 7: ...ts own receiver RECEIVER AUDIO CONNECTIONS First determine which audio inputs are available on your mixer next decide how to connect the receiver To a balanced MIC input of the audio mixer close the gain of the mixer input and set the mic line switch on the receiver 7 to MIC Use an XLR XLR cable to connect the receiver XLR output 5 Switch the transmitter hand mic belt pack on and bring the in put ...

Страница 8: ...the audio level with the gain knob 7 While checking the system walk around to check if you encounter any dead spots no reception in these cases try to change the position of the receiver SEVERAL SETS WORKING TOGETHER SETUP NOTES Even if the transmitters and receiver have 16 channels you cannot use 16 wireless systems together de pending on the situation you will be able to use maximum 6 sets toget...

Страница 9: ... 4 1 2007 11 EN 60065 2002 A1 2006 A11 2008 Full test reports and other relevant information remain at the disposal of the Control Agencies at our head office Beglec NV t Hofveld 2c B1702 Groot Bijgaarden Belgium Groot Bijgaarden July 25th 2009 For Beglec NV Luc De Bauw Director WIRELESS HAND MICRO R TTE Declaration of Conformity We Beglec NV declare under our sole responsibility that the product ...

Страница 10: ...Hz S N ratio 94dB 20kHz deviation 60 V antenna input AF Response 80Hz to 15kHz 3dB T H D Less than 1 0 at 1kHz Power Supply DC 12V 18V Audio Output Balanced unbalanced outputs Mic 20dB Line 0dB Current consumption 130mA 10mA HANDHELD MIC BELT PACK TRANSMITTER Carrier Frequency Range UHF band RF Power Output 10mW max Oscillation Mode PLL synthesized 16Channel selectable Frequency Stability 0 005 Ma...

Страница 11: ......

Страница 12: ......

Отзывы: