background image

ENGLISH

OPERATION MANUAL

JB SYSTEMS

®

3/52

iROCK 5C

LAMP (RE)PLACEMENT

In case of replacement of the lamp or
maintenance, do not open the fixture
within 10 minutes until the unit cools
down

after switching

off.

Always

unplug the unit before servicing! Always use the
same type of spare parts (bulbs, fuses, etc.)
When replacing parts, please only genuine spare
parts.

Switch off the unit and unplug the mains cable.

Wait for about 10 minutes until the unit has been
cooled down.

Unscrew the

2

screws

that close the lamp

compartment on the back of the fixture. (number 1
on the picture )

On the inside you will see the lamp socket. Tear the
lamp socket gently out of the lamp compartment.

Unplug the old lamp. Hold the lamp socket while
unplugging the lamp

Hold the lamp socket while pressing the new lamp
gently in the socket.

Attention!

Check the label on the backside of the

device or see the technical specifications in this
manual to know which lamp should be used.
Never install lamps with a higher wattage! Lamps
with higher wattage generate temperatures the
device was not designed for. If the device uses a
lamp transformer, it will burn due to current
overload.

Don’t touch the bulb with bare hands! This
drastically shortens the lifespan of the lamp. If you
touched the lamp, clean it with a cloth and a little
denatured alcohol. Wipe the lamp off before
installing.

Put the new lamp back inside the unit. Be sure that the wires don’t touch the lamp.

Close the lamp compartment with the screws.

Turn on the unit and point the beam to a white surface. Use the three adjustment screws indicated by
“lamp adjust”. Gently turn these three screws until you obtain maximum light output.

Done!

EXCHANGING/ROTATING GOBOS

ATTENTION: Install the gobos only when the unit is switched off!
Never unscrew the screws of the rotating gobo as the ball bearing will be opened. Repairing
this is very difficult!

Switch off the main supply and unplug the unit.

Open the plastic top cover (4screws)

Locate the gobo wheel and remove the fixation ring
of the gobo you want to change with an appropriate
tool.

Remove the gobo and insert the new gobo.

Press the fixation-ring together and insert it in the
front of the gobo.

Done!

ENGLISH

OPERATION MANUAL

JB SYSTEMS

®

4/52

iROCK 5C

OVERHEAD RIGGING

Important: The installation must be carried out by qualified service personal only. Improper
installation can result in serious injuries and/or damage to property. Overhead rigging requires
extensive experience! Working load limits should be respected, certified installation materials
should be used, the installed device should be inspected regularly for safety.

Make sure the area below the installation place is free from unwanted persons during rigging, de-rigging
and servicing.

Locate the fixture in a well ventilated spot, far away from any flammable materials and/or liquids. The
fixture must be fixed

at least 50cm

from surrounding walls.

The device should be installed out of reach of people and outside areas where persons may walk by or be
seated.

Before rigging make sure that the installation area can hold a minimum point load of 10times the device’s
weight.

Always use a certified safety cable that can hold 12times the weight of the device when installing the unit.
This secondary safety attachment should be installed in a way that no part of the installation can drop
more than 20cm if the main attachment fails.

The device should be well fixed; a free-swinging mounting is dangerous and may not be considered!

Don’t cover any ventilation openings as this may result in overheating.

The operator has to make sure that the safety-relating and machine-technical installations are approved by
an expert before using them for the first time. The installations should be inspected every year by a skilled
person to be sure that safety is still optimal.

HOW TO SET UP THE UNIT

CONTROL PANEL:

1. DISPLAY

shows the various menus and the

selected functions.

2. LEDS

DMX

On

DMX input present

MASTER

On

Master mode

SLAVE

On

Slave mode

SOUND

Flashing

Sound activation

3. BUTTONS

MENU

To select the programming functions

DOWN

To go backward in the selected functions

UP

To go forward in the selected functions

ENTER

To confirm the selected functions

4. REMOTE CONTROL INPUT:

Used to connect a optional CA-8 hand controller while the unit is used in

standalone or master/slave mode.

Содержание iRock 5c

Страница 1: ...7 by BEGLEC cva Reproduction or publication of the content in any manner without express permission of the publisher is prohibited Operation Manual Mode d emploi Gebruiksaanwijzing Bedienungsanleitung...

Страница 2: ...t toestel en de gebruikte batterijen op een milieuvriendelijke manier conform de in uw land geldende voorschriften DU ENTSORGUNG DES GER TS Entsorgen Sie das Ger t und die Batterien auf umweltfreundli...

Страница 3: ...material as much as possible A new light effect sometimes causes some unwanted smoke and or smell This is normal and disappears after some minutes To prevent fire or shock hazard do not expose this a...

Страница 4: ...Remove the gobo and insert the new gobo Press the fixation ring together and insert it in the front of the gobo Done ENGLISH OPERATION MANUAL JB SYSTEMS 4 52 iROCK 5C OVERHEAD RIGGING Important The i...

Страница 5: ...fter 8 seconds To go back to the functions without any change press the MENU button again Color Mode Normal only full colors can be selected Split colors you can select full colors and 2 colors that a...

Страница 6: ...dress on this unit The starting address of each unit is very important Unfortunately it is impossible to tell you in this user manual which starting addresses you have to set because this completely d...

Страница 7: ...STEMS 10 52 iROCK 5C CAUTION Merci d avoir choisi ce produit JB Systems Pour votre s curit et pour une utilisation optimale de toutes les possibilit s de l appareil lisez attentivement cette notice av...

Страница 8: ...les L appareil doit tre la masse selon les r gles de s curit s Ne pas connecter l unit un variateur de lumi re Utilisez toujours les c bles appropri s et certifi s lorsque vous installez l unit Pour v...

Страница 9: ...LOI JB SYSTEMS 14 52 iROCK 5C 4 ENTREE POUR LE CONTROLEUR A DISTANCE connectez le contr leur distance optionnel CA 8 via l entr e jack afin de contr ler l appareil au niveau du stand by de la fonction...

Страница 10: ...l cran est teint quand il n est pas utilis Appuyez sur la touche MENU jusqu ce que l cran affiche Appuyez sur la touche ENTER l cran commence clignoter Utilisez les touches DOWN et UP pour s lectionne...

Страница 11: ...oir quelle adresse vous devez utiliser FRAN AIS MODE D EMPLOI JB SYSTEMS 18 52 iROCK 5C CONFIGURATION DMX DU IROCK 5C COMMENT UTILISER L APPAREIL Chaque fois que vous allumerez l appareil l cran affic...

Страница 12: ...rieur de l appareil doit tre nettoy annuellement l aide d un aspirateur ou jet d air Le nettoyage des lentilles optiques internes et externes et ou des miroirs doit tre effectu p riodiquement pour opt...

Страница 13: ...mafstand van te belichten voorwerpen De minimumafstand tussen projector en het verlichte voorwerp moet meer dan 1 meters zijn Om het milieu te beschermen probeer zoveel mogelijk het verpakkingsmateria...

Страница 14: ...djust op het toestel Draai deze 3 schroeven zachtjes tot wanneer u een maximale lichtuitstoot verkrijgt Klaar NEDERLANDS HANDLEIDING JB SYSTEMS 24 52 iROCK 5C ROTERENDE GOBOS VERVANGEN OPGELET Install...

Страница 15: ...keert hij na 8 seconden automatisch weer naar de hoofdfuncties zonder iets gewijzigd te hebben Om naar de functies terug te keren zonder iets te wijzigen moet u weer op de MENU toets drukken Slave Mo...

Страница 16: ...entrale positie U kunt de focus instellen met de UP DOWN toetsen op de display wordt de focuswaarde weergegeven Druk op de MENU toets om naar de functies weer te keren Self Test Wordt gebruikt om het...

Страница 17: ...onder de installatieplaats vrij is van ongewenste personen tijdens het onderhoud Zet het toestel uit trek de netstekker uit het stopcontact en wacht tot het toestel is afgekoeld Bij inspectie moeten...

Страница 18: ...X Kan le Farbe Gobo Gobo Rotation Shutter Dimmer Die DMX Start Adresse kann ber den ILEAD Controller eingestellt werden Ausgezeichnete Optik f r randscharfe Goboabbildung und hohen Lichtaustritt 9 dic...

Страница 19: ...t mit anderen Kabeln in Ber hrung kommen lassen Zur Einhaltung der Sicherheitsbestimmungen mu das Ger t geerdet sein Ger t nicht an einen Dimmer anschlie en Ausschlie lich vorschriftsm ige Kabel zur I...

Страница 20: ...TUNG JB SYSTEMS 36 52 iROCK 5C 4 EingangFernsteuerung Schlie en Sie die wahlweise CA 8 Fernsteuerung an der 1 4 Mikrofonbuchse zur Steuerung von Stand by Funktion und Modus an 5 EMPFINDLICHKEIT Zur Ei...

Страница 21: ...Normal Display Mit EINGABE ENTER zu Betriebsart Display Umkehrung umschalten die Einstellung wird nach 8 Sekunden automatisch gespeichert oder EINGABE ENTER erneut dr cken und so zu Normal Display zu...

Страница 22: ...8 Easy Controller Diesen kleinen Controller einfach an der 1 4 Buchse des Hauptger ts anschlie en und dann folgende Funktionen steuern WARTUNG UND INSTANDHALTUNG Sicherstellen dass sich keine unbefug...

Страница 23: ...icos blanco Apag n blackout dimerizado 0 100 y estrobo de alta velocidad ajustable Funciona con s lo conectar el mando CA 8 opcional Control sencillo con iLEAD SM1612 o cualquier otro controlador DMX...

Страница 24: ...gado cuando instale la unidad Para evitar descargas el ctricas no abra la cubierta Adem s de la l mpara y el fusible de red no hay piezas en el interior de este aparato que pueda mantener el usuario N...

Страница 25: ...TER Para confirmar las funciones seleccionadas 4 Entrada de control remoto Se utiliza para conectar un controlador manual CA 8 opcional mientras la ESPA OL MANUAL DE INSTRUCCIONES JB SYSTEMS 46 52 iRO...

Страница 26: ...est encendida Pantalla apagada la pantalla est apagada cuando no se utiliza Pulse el bot n MENU hasta que la pantalla muestre Pulse el bot n ENTER la pantalla comienza a parpadear Utilice los botones...

Страница 27: ...RUCCIONES JB SYSTEMS 50 52 iROCK 5C CONFIGURACI N DMXDE IROCK5C MANEJO DE LA UNIDAD Cada vez que encienda la unidad se mostrar Ir5c en la pantalla todos los motores volver n a su posici n original y p...

Страница 28: ...de instalaci n techo suspensiones no deber n presentar ningunadeformidad Cuando una lente ptica est visiblemente da ada por grietas o rasgu os profundos deber ser reemplazada Los cables de red deber n...

Отзывы: