ENGLISH
OPERATION MANUAL
JB SYSTEMS
®
5/52
iROCK 5C
5. SENSITIVITY:
Used to adjust the sensitivity of the micro when the unit is used in standalone or
master/slave mode.
6. MICROPHONE:
used to trigger the internal programs to the rhythm of the music.
7. DMX INPUT/OUTPUT:
used for DMX512 linking. Use good quality 3pin XLR M/F balanced cable to link
the units together.
MAIN MENU:
To select any of the pre-set functions, press
the
MENU
button up to when the required one
is shown on the display.
Select the function with the
ENTER
button.
The display will blink.
Use
DOWN
and
UP
button to change the
mode.
Once the required mode has been selected,
press the
ENTER
button to select. After 8
seconds the display will automatically return to
the main functions without any change. To go
back to the functions without any change press
the
MENU
button. The main functions are
shown on the right.
DMX512 Address Setting
Used to set the starting address in a DMX
setup.
Press the MENU button until
is shown
on the display.
Press the ENTER button, the display starts
blinking.
Use DOWN and UP buttons to change the
DMX512 address.
Once the correct address shows on the
display, press the ENTER button to save it.
(or automatically return to the main functions
without any change after 8 seconds)
To go back to the functions without any change press the MENU button again.
Slave Mode
Used to make the slave unit work in opposite to the master or to work in complete sync.
Press the MENU button until
is shown on the display.
Press the ENTER button, the display starts blinking.
Use DOWN and UP button to select
(normal) ,
(2 light show) mode,
(3 light show)
mode or
(4 light show).
Once the mode has been selected, press the ENTER button save it.
(or automatically return to the main functions without any change after 8 seconds)
To go back to the functions without any change press the MENU button again.
Blackout Mode
Blackout mode: when no DMX-signal is detected, the unit goes in blackout and waits for the DMX-
signal.
No blackout mode: when no DMX-signal is detected, the unit automatically switches to standalone
mode.
Press the MENU button until
is shown on the display.
Press the ENTER button, the display starts blinking.
ENGLISH
OPERATION MANUAL
JB SYSTEMS
®
6/52
iROCK 5C
Use DOWN and UP button to select
(yes blackout) or
(no blackout) mode.
Once the mode has been selected, press the ENTER button to save it.
(or automatically return to the main functions without any change after 8 seconds)
To go back to the functions without any change press the MENU button again.
Color Mode
Normal: only full colors can be selected.
Split colors: you can select full colors and 2 colors that are next to each other on the color wheel.
Press the MENU button unitl
is shown on the display.
Press the ENTER button, the display starts blinking.
Use DOWN and UP button to select
(normal) or
(split color) mode.
Once the mode has been selected, press the ENTER button to save it.
(or automatically return to the main functions without any change after 8 seconds)
To go back to the functions without any change press the MENU button again.
Dimmer Inversion
Standard dimming:
fader closed ( DMX value 000 )
full light output
fader open ( DMX value 255 )
blackout
Inversed dimming:
fader closed ( DMX value 000 )
blackout
fader open ( DMX value 255 )
full light output
Press the MENU button up to when the
is shown on the display.
Press the ENTER button so the display starts blinking.
Use DOWN and UP buttons to select the
(normal) or
(dimmer inversion) mode.
Once the mode has been selected, press the ENTER button to save it. ( or automatically return to the
main functions without any change after 8 seconds )
To go back to the functions without any change press the MENU button again.
Led Display
Display on: display is always on.
Display off: display is off when not used.
Press the MENU button until the display shows
.
Press the ENTER button, the display starts blinking.
Use DOWN and UP buttons to select
(display always on) or
(display off when not used).
Once the mode has been selected, press the ENTER button to save it. The led display stops working after
about 40 seconds
(or automatically return to the main functions without any change after 8 seconds)
To go back to the functions without any change press the MENU button again.
Display Inversion
Display normal: display is readable when the unit is on the floor.
Display inversion: display is readable when the unit is mounted upside down.
Press the MENU button untill
is blinking on the display. (normal display)
Use the ENTER button to change to the mode
(display inversion), the option will be automatically
stored after 8 seconds. Or press the ENTER button again return to the mode
(normal display).
To go back to the functions press the MENU button.
Focus Adjust
Used to help you adjusting the focus of the light beam and gobos.
Press the MENU button untill
is blinking on the display.
Press the ENTER button and the unit will focus on center position
You are able to adjust the focus with the UP/DOWN buttons on the unit (the display shows the current focus
status).
To go back to the functions press the MENU button.