76
Section 5: Slideout Systems
Preventative Maintenance:
The Power Gear® slideout system requires very little maintenance. Read and follow these
procedures:
When the room is extended, visually inspect the slide rail assemblies. Check for
excess buildup of dirt or foreign material; remove any debris that may be present.
If the system squeaks or makes any noises, blow out any debris from the gear rack
arms and apply a dry lubricant to prevent and/or stop squeaking.
Refer to the Power Gear® website (
) for additional information.
Override Modes:
In the event of component failure or loss of system power, your slideout can be manually
overridden and retracted for travel.
Emergency Retract Mode:
Use this procedure when there is
NO
loss of power or electrical problem with the system.
1.
Remove the touchpad (Fig 4) from the wall.
2.
Prior to clearing the MAJOR fault, record the number of
RED & GREEN flashes observed on the touchpad (Fig 6).
This information will help your dealer/service center in
troubleshooting the slideout system.
3.
Press and hold the SET STOPS/CLEAR FAULTS button
on the back of the touchpad for five (5) seconds (Fig 2). Both RED & GREEN LEDs
will be on solid while pressing this button. After 5 seconds, the GREEN LED will
begin flashing and the RED LED will remain solid on.
4.
The unit is now ready to retract the room. Press and hold the ROOM SLIDEOUT MO-
TOR buttons 1 and 2 on the back of the touchpad (Fig 3).
It is very important to note that during this procedure, the slideout control
has NO stop locations. Use a second person to assist in determining when
the room is retracted. Damage to the room can occur if the room is retracted
too far.
NOTE:
During the override procedure, the unit will exit this mode
if the room has not been moved for two (2) minutes or if a fault is
detected during room movement. The Fault Code (RED) and Room
or Lock Movement (GREEN) LEDs will flash rapidly for 10 seconds to
indicate the override procedure failed. After 10 seconds of flashing,
the control will automatically default to FAULT CODE 1. Program
-
ming must be restarted.
NOTE:
After overriding the system, the room control will need to be
re-programmed by an OEM authorized dealer.
Maintenance Record
Table of Contents
Содержание PINNACLE FIFTH WHEELS 2019
Страница 1: ...2016 CAMPING TRAILERS 2019 FIFTH WHEELS Owner s Manual PRINTED ON RECYCLED PAPER 0210677 2019...
Страница 2: ......
Страница 4: ......
Страница 12: ...10 Maintenance Record Table of Contents...
Страница 40: ...38 Section 3 Pre Travel Information Notes Maintenance Record Table of Contents...
Страница 82: ...80 Section 5 Slideout Systems Maintenance Record Table of Contents...
Страница 112: ...110 Section 7 Fuel Propane System Maintenance Record Table of Contents...
Страница 148: ...146 Section 9 Heating Cooling Maintenance Record Table of Contents...
Страница 160: ...158 Section 10 Appliances Notes Maintenance Record Table of Contents...
Страница 180: ...178 Section 14 Travel Camping Storage Checklists Notes Maintenance Record Table of Contents...
Страница 185: ...183 Section 15 Additional Information Notes Table of Contents Maintenance Record...