131
Section 8: Plumbing System
To prevent a water leak when replacing the anode rod, a pipe thread sealant approved for
potable water (such as Teflon tape) must be applied to the threads of the anode rod. Proper
application of a thread sealant will not interfere with the anode’s function.
High altitude deration
Operation of the water heater at high altitudes may require derating. If the water heater is
not properly derated, lack of sufficient oxygen for combustion may produce improper burn
-
er operation. Pilot outage caused by burner lift-off or sooting from a yellow burner may
occur, indicating the possibility of carbon monoxide. You may also notice a lack of effi
-
ciency in heating the water because of incomplete combustion of the burner at these higher
altitudes. Consult with the local propane company, your dealer or the water heater manufac-
turer for proper derating of the water heater. Change out of the orifice (derating) should be
done by the dealer or a qualified service agency.
Pressure and temperature relief valve
The temperature and pressure relief valve is designed to open if the temperature of the water
within the heater reaches 120° F, or if the water pressure in the heater reaches 150 pounds.
When this pressure is reached, the pressure relief valve will open and water will drip from
the valve.
This “weeping” or dripping will continue until the pressure is reduced to below 150 pounds,
and the valve closes. This condition is normal and does not indicate a defective relief valve.
One way to reduce the frequency of this occurrence is to maintain an air pocket at the top
of the water heater tank. This air pocket will form in the tank by design; however, it will be
reduced over time by the everyday use of your water heater. To replenish this air pocket:
1.
Turn off the water heater.
2.
Turn off the cold water supply line.
3.
Open a faucet in the RV.
4.
Pull out the handle of the pressure relief (P&T) valve and allow water to flow from the
valve until it stops.
5.
Release the handle on the P&T valve - it should snap closed.
Close the faucet and turn on the cold water supply. As the tank fills, the air pocket will
develop. Repeat this procedure as often as needed to reduce the frequency of the weeping
P&T valve.
Maintenance
Do not allow the burner to burn with a yellow flame, or continue to operate the water heater
with an improper burner flame.
NOTE:
It is important that once the RV has returned to lower
elevation (below 4500 feet) any high altitude deration or other adjust
-
ments be reversed for proper operation of the water heater.
Do not place a valve between the pressure and temperature (P&T) valve and
the tank. Do not remove or plug the relief valve under any circumstances.
Table of Contents
Maintenance Record
Содержание PINNACLE FIFTH WHEELS 2019
Страница 1: ...2016 CAMPING TRAILERS 2019 FIFTH WHEELS Owner s Manual PRINTED ON RECYCLED PAPER 0210677 2019...
Страница 2: ......
Страница 4: ......
Страница 12: ...10 Maintenance Record Table of Contents...
Страница 40: ...38 Section 3 Pre Travel Information Notes Maintenance Record Table of Contents...
Страница 82: ...80 Section 5 Slideout Systems Maintenance Record Table of Contents...
Страница 112: ...110 Section 7 Fuel Propane System Maintenance Record Table of Contents...
Страница 148: ...146 Section 9 Heating Cooling Maintenance Record Table of Contents...
Страница 160: ...158 Section 10 Appliances Notes Maintenance Record Table of Contents...
Страница 180: ...178 Section 14 Travel Camping Storage Checklists Notes Maintenance Record Table of Contents...
Страница 185: ...183 Section 15 Additional Information Notes Table of Contents Maintenance Record...