75
Section 5: Slideout Systems
or the IN button when fully retracted, and stops moving.
9.
Turn
OFF
the on/off switch or key.
Fault Diagnostics / Troubleshooting:
The control has the ability to detect and display sev
-
eral faults. When a fault is detected, room movement stops and two different LEDs will
flash in a pattern.
The RED FAULT CODE LED (Fig 4) will flash a number of times corresponding to a spe
-
cific fault code (refer to the Fault Code Chart).
The GREEN ROOM MOVEMENT LED (Fig 4) will flash GREEN a number of times cor
-
responding to which motor has the associated fault.
Example: (4) RED flashes and (2) GREEN flashes indicate a motor fault on motor 2.
MAJOR and MINOR faults
; faults must be cleared for the room to operate normally.
MINOR
faults can be cleared by pushing and releasing the
IN
or
OUT
buttons on
the wall touchpad (Fig 4).
MAJOR
faults must be cleared by pushing and releasing the SET STOPS/CLEAR
FAULTS button located on the back of the wall touchpad (Fig 2).
Fault
Code
Fault
Type
Fault Codes
Description
Possible Cause
Possible Solution
1
Major
Stops not programmed
-Stops have not been set
-Stops were cleared
-Stops were improperly set
Steps need to be programmed by an
authorized service facility.
2
Minor
System Fault
-Obstruction present
-Excessive system drag
Run room in opposite direction. If it
continues to move in the opposite direction,
remove obstruction, excessive weight in
room or repair of damaged component. If
room stops moving in opposite direction,
observe fault code and refer to this chart
4
Major
Excessive Battery
Voltage
-Bad or loose connection
-Defective harness
-Open or shorted motor
-Check all connections at control box
and motor
-Check the harness for broken wires.
-Put 12.0 VDC direct to the motor. If it
does not run replace the motor.
6
Minor
Supply voltage to control box is 17
0 V DC or greater
Check 2-pin power connector at control box.
If the voltage is 17. VDC or higher, contact
O.E.M for power and ground supplies
Park brake LED flashing
-Parking brake not set (if
applicable)
-Ground signal lost at park
brake control
-Set parking brake (if applicable)
-Check for continuity to ground on wire
plugged into park brake connector at
control box
Low voltage LED flashing
Incoming violated to control box is
below 12.0 VDC
Check 2-pin power connector at control box.
If voltage is below 12.0 VDC contact O.E.M
for power and ground supplies.
NOTE:
For MAJOR faults, the control must be overridden by
following the EMERGENCY RETRACT MODE in the OVERRIDE
MODES section.
Table of Contents
Maintenance Record
Содержание PINNACLE FIFTH WHEELS 2019
Страница 1: ...2016 CAMPING TRAILERS 2019 FIFTH WHEELS Owner s Manual PRINTED ON RECYCLED PAPER 0210677 2019...
Страница 2: ......
Страница 4: ......
Страница 12: ...10 Maintenance Record Table of Contents...
Страница 40: ...38 Section 3 Pre Travel Information Notes Maintenance Record Table of Contents...
Страница 82: ...80 Section 5 Slideout Systems Maintenance Record Table of Contents...
Страница 112: ...110 Section 7 Fuel Propane System Maintenance Record Table of Contents...
Страница 148: ...146 Section 9 Heating Cooling Maintenance Record Table of Contents...
Страница 160: ...158 Section 10 Appliances Notes Maintenance Record Table of Contents...
Страница 180: ...178 Section 14 Travel Camping Storage Checklists Notes Maintenance Record Table of Contents...
Страница 185: ...183 Section 15 Additional Information Notes Table of Contents Maintenance Record...