reaches them. They are not foolproof. Do not
remove the following label from your RV:
Operation
The factory-installed ceiling mounted smoke
alarm is operational once the 9-volt battery is
correctly connected. The LED will flash to
show the battery is supplying power to the
alarm. When the product of combustion is
sensed, the smoke alarm sounds a loud alarm
that continues until the air is cleared.
How to test
Stand at arm’s length from the smoke alarm
when testing. The alarm horn is loud and may
be harmful to your hearing. The test button will
accurately test all functions. Never use an
open flame from a match or lighter to test the
smoke alarm; you may ignite and set fire to the
smoke alarm and your RV. If the smoke alarm
does not test properly, replace it immediately.
Battery
The smoke alarm will not function if the battery
is missing, disconnected, dead, the wrong
type of battery is used or the battery is installed
incorrectly. When the battery becomes weak,
the smoke alarm will “beep” (the low battery
warning). If the low battery warning sounds,
the
battery
MUST
be
replaced.
Never
disconnect the battery to silence the smoke
alarm.
C
ARBON
M
ONOXIDE
A
LARM
Carbon monoxide (CO) is an insidious poison.
It is a colorless, odorless and tasteless gas.
Many cases of reported carbon monoxide
poisoning indicate while victims are aware
they are not well, they become so disoriented
they are unable to save themselves by either
exiting the RV or calling for assistance. Young
children and household pets may be the first
affected.
The CO alarm is designed to detect the toxic
carbon monoxide fumes that result from
incomplete combustion, such as those emitted
from appliances, furnaces, fireplaces and auto
exhaust. A CO alarm is
NOT A SUBSTITUTE
for other combustible gas, fire or smoke
alarms.
14
SECTION 2
OCCUPANT SAFETY
The following symptoms are related to
carbon monoxide poisoning and should be
discussed
with
all
members
of
the
household:
Mild exposure
– Slight headache, nausea,
vomiting,
fatigue
(often
described
as
"flu-like" symptoms).
Medium exposure
– Throbbing headaches,
drowsiness, confusion, fast heart rate.
Extreme
exposure
–
Convulsions,
unconsciousness, heart and lung failure.
Exposure to carbon monoxide can cause
brain damage, death.
WARNING
If you are in a RV with either a nearby tow
vehicle engine running or the generator (if
so equipped) running there is a potential for
exhaust fumes to filter back into the RV.
Avoid inhaling exhaust gases as they
contain carbon monoxide, which is a
potentially toxic gas that is colorless and
odorless.
TEST SMOKE ALARM OPERATION AFTER
VEHICLE HAS BEEN IN STORAGE,
BEFORE EACH TRIP, AND AT LEAST
ONCE PER WEEK DURING USE.
FAILURE TO COMPLY MAY RESULT IN
SERIOUS INJURY.
0173019
WARNING
Fig 2.2 Smoke alarm label
Содержание 2008 Octane ZX
Страница 1: ...www jayco com Sport Utility Trailer Owner s Manual Model Year 2008...
Страница 9: ...5 SECTION 1 WARRANTY SERVICE...
Страница 22: ...THIS PAGE IS INTENTIONALLY BLANK 18 SECTION 2 OCCUPANT SAFETY...
Страница 40: ...THIS PAGE IS INTENTIONALLY BLANK 36 SECTION 5 RV TIRES...
Страница 50: ...THIS PAGE IS INTENTIONALLY BLANK 46 SECTION 7 FUEL SYSTEM...
Страница 62: ...THIS PAGE IS INTENTIONALLY BLANK 58 SECTION 8 PLUMBING SYSTEM...
Страница 70: ...THIS PAGE IS INTENTIONALLY BLANK 66 SECTION 9 PROPANE SYSTEM...
Страница 84: ...THIS PAGE IS INTENTIONALLY BLANK 80 SECTION 10 CAMPING OPERATING...
Страница 102: ...THIS PAGE IS INTENTIONALLY BLANK 98 SECTION 10 SPECIFICATIONS GLOSSARY...
Страница 103: ...There are no addendums issued at this time 99 SECTION 13 ADDENDUMS...
Страница 104: ...THIS PAGE IS INTENTIONALLY BLANK 100 SECTION 13 ADDENDUMS...