charge pump
■
shut-off valve
To facilitate any future servicing.
■
enclosed filterball (QZ2)
Installed before connection "heating medium return"
(XL2) (the lower connection) on the vacuum pump.
■
reversing valve.
When connecting to the control module, and if the
system is to be able to work with both the climate
system and the hot water heater.
■
trim valve
When connecting to control module and hot water
heater.
Vent the heat pump by the "heating medium supply"
connection (XL1) using the venting nipple on the en-
closed flexible hose.
P
XL1
XL2
The image shows connection to the control module.
Charge pump
The charge pump (not included in the product) is
powered and controlled from the indoor module/control
module. It has a built-in frost protection function and,
for this reason, must not be switched off when there is
a risk of freezing.
At temperatures below +2 °C the charge pump runs
periodically, to prevent the water from freezing in the
charge circuit. The function also protects against excess
temperatures in the charge circuit.
Pressure drop, condenser
JÄSPI Inverter Nordic-8, -12, -16, -20
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
0 0,05 0,1 0,15 0,2 0,25 0,3 0,35 0,4 0,45 0,5 0,55 0,6 0,65 0,7 0,75 0,8 0,85 0,9
Tryckfall
[kPa]
Flöde [l/s]
Tryckfall F2120
Pressure drop
(kPa)
Flow
(l/s)
-12/-16/-20
-8
Pipe insulation
LEK
Heat insulation
All outdoor pipes must be insulated with at least 19 mm
thick pipe insulation.
Installing flex hoses
LEK
Data
Serie.nr
.
Art.nr
. 711
453
OUT
IN
XL1
XL2
21
Chapter 4 |
Pipe connections
JÄSPI Inverter Nordic