15. There is deviation between
the preset value and real value
of the show value of the meter.
a. The value of the variable resistor R9 on
control PCB PK-05-A4 or VR1 on preset
PCB PH-10-A01 changes.
a. Adjust. Methods: 1. Turn to ARC
mode, adjust the value of variable
resistor R9 on control PCB
PK-05-A4 to make the show value
of the meter be the value of the
corresponding machine type. 2.
Turn to TIG mode, do not press
the manual switch, adjust the
value of variable resistor VR1 on
preset PCB PH-10-A0 to make the
show value of the meter be the
value of the corresponding
machine type.
16. No pulse when in pulse
mode.
a. The panel pulse conversion switch is
damaged.
b. The connecting cable matching socket
CON2/CON3 on control panel PK-31-A0
with the pulse conversion switch is
short-circuited, or chip U4, capacitor
C4/C11, potentiometer VR2/VR3 or diode
D24 is damaged.
a. Check and replace it if necessary.
b. Check.
17. When no-load in ARC
mode, it appears normal in DC
mode, but there is abnormal
sound in AC mode.
a. Some MOSFET on the secondary
inverter PCB PN-05-A2/PN-06-A1 is
damaged.
a. Check. Method: Turn to ARC
mode, then AC mode, turn off the
machine after 3mins of no-load,
touch the MOSFET on the
secondary inverter PCB with your
hand one by one. The extra hot
ones are damaged.
18. No 4T state or 4T is
inaccurate.
a. The 2T/4T conversion switch on the
panel is damaged, or the connecting
cable matching it with socket CON10 on
control panel PK-31-A0 is in loose
connection.
b. Some part on control panel PK-31-A0 is
damaged.
a. Check.
b. Check if chip U8/U2, diode D6 or
capacitor C2 on control panel is
damaged.