2. Turn on the machine, the
meter displays, press the
welding torch switch in TIG
mode, there is gas out, no HF,
turn to ARC mode, no no-load
voltage output.
a. The connecting cable matching socket
CON7/CON8 on bottom PCB PZ-03-B0
is in loose connection.
b.
The prime relay RELAY1 on bottom PCB
PZ-03-B0 doesn’t close well; the value of
resistor RT1/RT2 increases.
c. The connecting cable matching socket
CON2/CON4/CON5 on bottom PCB
PZ-03-B0 with rectifying bridge is in loose
connection.
d. Some part on control module PK-03-A1 is
damaged.
e. Some part on control PCB PK-05-A4 is
damaged.
a. Check and make sure the voltage
of socket CON1 is DC532V.
b. Check and replace if necessary.
c. Check.
d. Check with a multi-meter if chip
U1 on PK-03-A1 is damaged.
Check if the 16
th
pin of U1 is 5V. If
it’s not, replace the chip because
U1 is damaged. Check if diode
D2/D3/D4, audion Q2/Q3/Q4/Q5/
Q6/Q7/Q9, thyristor Q1, zener
diode Z1/Z2/Z3, capacitor C17 or
resistor R32 is damaged.
e. Check if MOSFET U2/U3/U4/U5
or resistor R32 is damaged.
3. Turn on the machine, the
meter displays, but the thermal
resistor RT1/RT2 on bottom
PCB PZ-03-B0 heats and
smokes after a while.
a. The connecting cable (+24V) matching
socket CON1 on bottom PCB PZ-03-B0
with socket CON14 on control PCB
PK-05-A4 is in loose connection.
b. The relay RELAY1 on bottom PCB
PZ-03-B0 is damaged.
c. The auxiliary power supply part on
control PCB PK-05-A4 is damaged.
a. Check.
b. Check.
c. Check with a multi-meter if
resistor R35, MOSFET U1, audion
Q2, chip U6 or capacitor C32 on
control PCB PK-05-A4 is
damaged.