22. When the pulse conversion
switch is at no-pulse state, in
ARC/TIG mode, the welding
current is invariable, and there
is only maximum current.
a. The diode D24 on control panel
PK-31-A0 is damaged.
a. Check and replace it if necessary.
23. Turn on the machine, the
indicator of protection status is
on because the voltage is too
low.
a. The input voltage is too low or is
unstable.
b. The thermal switch matching socket
CON14 on control panel PK-31-A0 is
damaged.
c. The connecting cable matching socket
CON15 on control panel PK-31-A0 is in
loose connection.
d. The resistor R51/R44 or chip U6 on
control panel PK-31-A0 is damaged.
a. Check.
b. Check.
c. Check.
d. Check. Method: properly reduce
the value of resistor R44.
24. The tungsten is badly
burned out in AC mode.
a. The value of AC clean width on the panel
is adjusted too big.
a. Adjust the clean width smaller.
25. The manual control is
normal, but the pedal control
goes wrong.
a. The connecting cable matching socket
CON4 on control panel PK-31-A0 is in
loose connection.
b. Some part on control panel PK-31-A0 is
damaged.
a. Check.
b. Check if diode D23, zener diode
Z5, resistor R32/R35/R46 or
inductor L3/L4 on control panel
PK-31-A0 is damaged.