4.4 Troubleshooting of AC/DC315P/250P:
Trouble Analysis
Solution
1. Turn on the machine, no
display of the meter, the fan
doesn’t work, no no-load
voltage output in TIG/ARC
mode.
a. The input voltage is abnormal.
b. The power supply cable is not in good
connection with CP1/CP3 on bottom PCB
PZ-03-B0, or the tie-in is damaged.
c. The power supply switch may be
damaged or unclosed.
d. The connecting cable matching socket
CON1-CON6 on power supply
conversion PCB PH-20-A1 is in loose
connection.
a. Check if the input voltage is AC
380V.
b. Check.
c. Check and replace it if necessary.
d. Check.