OPTICELL 4 PRO AIR MATTRESS SYSTEM

The product is designed to help prevent and treat pressure ulcers from Categories 1-4 (low 
risk to very high risk) for patients within the weight range 0-250 kg.

The product is intended for use with a sheet between the patient’s skin and the mattress surface.

The mattress can be used within the following environments, defined by IEC 60601-2-52:

•  Operating environment 1 

(emergency care)

.

•  Operating environment 2 

(short-term care in hospitals or other healthcare facilities)

.

•  Operating environment 3

 (long-term care in healthcare facilities)

.

•  Operating environment 4 

(care in the home environment)

.

•  Operating environment 5 

(outpatient care)

.

In accordance with directives from the European and the US National Pressure Ulcer Advisory Panels 

(EPUAP and NPUAP), it is recommended that each patient’s condition be checked regularly.

PREPARATION

This user guide contains information for general use, maintenance and improved safety.  

It is very important to read this guide carefully before using the product. Care personnel must be 
given access to this user guide and also be informed of the risks that may arise when using electrical 
equipment. Training on the product can be provided on request. 

Before using the product for the first time, or when it is retrieved from a storage location:

•  Check the condition of the electrical system and its compliance with applicable safety 

standards.

•  Connect the product to the mains power supply.

•  The power outlet used should be easily accessible so that the product can be disconnected 

if necessary.

•  Ensure that all of the product’s functions are in good working order.

•  Ensure that the product and the care environment are in good hygienic condition.

•  Check that the product is positioned in a safe manner in the care environment.

•  Carry out a Hand Check test (see page 11).

If the mattress is used with other medical devices, it is the user’s responsibility to meet all relevant 
safety and compliance requirements.

Järven Health Care recommend that the product is disinfected before the first use.

Содержание OptiCell 4 PRO

Страница 1: ...1 USER GUIDE OptiCell 4 PRO Alternating pressure air mattress...

Страница 2: ...roduct 8 Receiving and unpacking 8 Storage 8 Automatic adjustment and alternating pressure 9 Static mode 9 Low pressure alarm 9 Air hose connection 10 Hand Check test 11 Inspection and troubleshooting...

Страница 3: ...e CE marking signifies that OptiCell AB has the manufacturer s responsibility to ensure that this product meets the essential requirements of relevant European legislation This includes the provision...

Страница 4: ...ment of the intended usage environment and then use the right product Please contact us if you have any questions In order to avoid damage the mattress should not come into contact with heat sources o...

Страница 5: ...use maintenance and improved safety It is very important to read this guide carefully before using the product Care personnel must be given access to this user guide and also be informed of the risks...

Страница 6: ...the bi elastic surface layer reduces the risk of shear and other complications for the patient Fluid protection flap and waterproof zip on four sides with welded seams Anti slip underside which grips...

Страница 7: ...ell 4 PRO air mattress is connected to the pump by three air hoses The red air hose positioned in the middle is used to fill the head cells situated under the patient s head It also fills the lower ch...

Страница 8: ...n mind that a tall patient can weigh the same as a short patient but may need a different pressure This must always be carefully observed for each patient The biggest risk for the patient is to bottom...

Страница 9: ...not want to be disturbed by an alternating pressure Press the Care Static button position E on page 14 to select either Care mode or Static mode Care also called Auto firm mode provides maximum pressu...

Страница 10: ...connector if the air hose is disconnected from the pump To minimise the risk of air leakage during hose connection check That the two hooks are not damaged and their clips are intact That the black o...

Страница 11: ...t is easier for the staff but it may give an incorrect test result Fold away the sheets and unzip the mattress cover to access the cells Put one hand between two cells with the patient lying on the ma...

Страница 12: ...r hoses for signs of damage or abnormal wear Check the air hose connector see page 10 INSPECTION OFTHE OPTITEX COVER Regularly check the cover for visible signs of damage or wear such as tears cracks...

Страница 13: ...d at a minimum of 70 C for at least 10 minutes with unscented detergent according to standard BS EN 14065 2016 Textiles Laundry Processed Textiles Biocontamination Control System The OptiTex cover can...

Страница 14: ...ng on the mattress is affected by the comfort mode chosen Press this button to cycle through modes ALARM If the alarm sounds press this button to mute and reset The adjacent Leaking lamp will light up...

Страница 15: ...out condensation Storage 10 90 without condensation Safety standard CE marked CARE STATIC Press this button to select Care auto firm mode or Static mode When the adjacent Care lamp is lit the pump pro...

Страница 16: ...posed of at a recycling station and sorted as Combustible waste For more information contact J rven HealthCare J rven Health Care takes environmental responsibility seriously We strive to always use m...

Страница 17: ...COMPLAINTS Any complaints regarding the product must be notified in writing to J rven Health Care The return of products must be done in accordance with our instructions Returning a product before a c...

Страница 18: ...essment is made to identify the specific needs of the patient regarding pressure relief and must be conducted by staff with adequate knowledge and education Based on the patient s assessed status the...

Страница 19: ...19 YOUR NOTES If you require any further information or assistance please get in touch with us We will be happy to help you...

Страница 20: ...e OPTICELL 4 PRO user guide All trademarks are the property of their respective owners J rven AB reserves the right to update this guide if necessary and or on finding any spelling or factual errors A...

Отзывы: