4

SAFETY INSTRUCTIONS

Read the following information before using your OptiCell 4 PRO mattress!

• 

The product should only be used in accordance with this user guide.

• 

The product should not be assembled, combined or repaired with any parts or 
accessories other than those described in this guide or in other documentation 
from Järven Health Care.

• 

Ensure that the mattress does not become misshapen or damaged during 
storage.

• 

Avoid sharp objects near the mattress so that the surface does not get 
damaged.

• 

Avoid severe physical impact from other objects.

• 

The mattress is fire safety tested according to standard 

SS 8760001

EN 597-1

 

and 

EN 597-2

. It is the customer’s responsibility to make a fire risk assessment 

of the intended usage environment and then use the right product. Please 
contact us if you have any questions.

• 

In order to avoid damage, the mattress should not come into contact with heat 
sources or fire, such as burning cigarettes, heat lamps or the like.

• 

Make sure that you use the correct mattress size for the bed and the 
appropriate model for the patient.

• 

Connect the product to the nearest situated power outlet in order to reduce 
the amount of power cable lying across the floor.

• 

Follow appropriate electrical safety standards.

• 

Always check electric cable before use

• 

Damaged or broken power cable must not be used.

THE PRODUCT MUST NOT BE USED FOR:

• 

Patients with unstable spinal fractures. For other unstable fractures, a medical 
examination is required to determine if it is appropriate to use the product.

• 

Patients with abnormal anatomies.

• 

Patients undergoing cervical traction or leg traction.

!

4

Содержание OptiCell 4 PRO

Страница 1: ...1 USER GUIDE OptiCell 4 PRO Alternating pressure air mattress...

Страница 2: ...roduct 8 Receiving and unpacking 8 Storage 8 Automatic adjustment and alternating pressure 9 Static mode 9 Low pressure alarm 9 Air hose connection 10 Hand Check test 11 Inspection and troubleshooting...

Страница 3: ...e CE marking signifies that OptiCell AB has the manufacturer s responsibility to ensure that this product meets the essential requirements of relevant European legislation This includes the provision...

Страница 4: ...ment of the intended usage environment and then use the right product Please contact us if you have any questions In order to avoid damage the mattress should not come into contact with heat sources o...

Страница 5: ...use maintenance and improved safety It is very important to read this guide carefully before using the product Care personnel must be given access to this user guide and also be informed of the risks...

Страница 6: ...the bi elastic surface layer reduces the risk of shear and other complications for the patient Fluid protection flap and waterproof zip on four sides with welded seams Anti slip underside which grips...

Страница 7: ...ell 4 PRO air mattress is connected to the pump by three air hoses The red air hose positioned in the middle is used to fill the head cells situated under the patient s head It also fills the lower ch...

Страница 8: ...n mind that a tall patient can weigh the same as a short patient but may need a different pressure This must always be carefully observed for each patient The biggest risk for the patient is to bottom...

Страница 9: ...not want to be disturbed by an alternating pressure Press the Care Static button position E on page 14 to select either Care mode or Static mode Care also called Auto firm mode provides maximum pressu...

Страница 10: ...connector if the air hose is disconnected from the pump To minimise the risk of air leakage during hose connection check That the two hooks are not damaged and their clips are intact That the black o...

Страница 11: ...t is easier for the staff but it may give an incorrect test result Fold away the sheets and unzip the mattress cover to access the cells Put one hand between two cells with the patient lying on the ma...

Страница 12: ...r hoses for signs of damage or abnormal wear Check the air hose connector see page 10 INSPECTION OFTHE OPTITEX COVER Regularly check the cover for visible signs of damage or wear such as tears cracks...

Страница 13: ...d at a minimum of 70 C for at least 10 minutes with unscented detergent according to standard BS EN 14065 2016 Textiles Laundry Processed Textiles Biocontamination Control System The OptiTex cover can...

Страница 14: ...ng on the mattress is affected by the comfort mode chosen Press this button to cycle through modes ALARM If the alarm sounds press this button to mute and reset The adjacent Leaking lamp will light up...

Страница 15: ...out condensation Storage 10 90 without condensation Safety standard CE marked CARE STATIC Press this button to select Care auto firm mode or Static mode When the adjacent Care lamp is lit the pump pro...

Страница 16: ...posed of at a recycling station and sorted as Combustible waste For more information contact J rven HealthCare J rven Health Care takes environmental responsibility seriously We strive to always use m...

Страница 17: ...COMPLAINTS Any complaints regarding the product must be notified in writing to J rven Health Care The return of products must be done in accordance with our instructions Returning a product before a c...

Страница 18: ...essment is made to identify the specific needs of the patient regarding pressure relief and must be conducted by staff with adequate knowledge and education Based on the patient s assessed status the...

Страница 19: ...19 YOUR NOTES If you require any further information or assistance please get in touch with us We will be happy to help you...

Страница 20: ...e OPTICELL 4 PRO user guide All trademarks are the property of their respective owners J rven AB reserves the right to update this guide if necessary and or on finding any spelling or factual errors A...

Отзывы: