Thank you for choosing the OptiCell 4 PRO alternating pressure air mattress from  
Järven Health Care. 

Our goal is for you to be satisfied with the mattress in terms of both function and service life. 
Therefore, please take a few minutes to read through this guide to understand the best way to 
manage and care for your mattress.

If you have any questions that are not answered here, please contact us at Järven Health Care.  
You can find our contact information at the back of this guide.

SYMBOLS USED THROUGHOUT THIS GUIDE

 

Important note:

 

 

All instructions denoted by this symbol must be observed. It highlights information 

 

and guidelines that are important to the user.

 

Risk of damage to mattress: 

 

Important information denoted by this symbol must be observed in order not to 

 

damage the mattress or other material.

CE MARKING

Järven Health Care hygiene mattresses are CE marked

 according to Medical Device 

Directive 93/42/EEC Class 1 (Medicintekniskt Direktiv 93/42/EEG). The CE marking signifies 
that OptiCell AB has the manufacturer’s responsibility to ensure that this product meets 
the essential requirements of relevant European legislation. This includes the provision of 
technical documentation and assurance which is maintained for at least five years after the 
product is placed on the market.

.

QUALITY

Our quality standards and customer focus goals

 are realised by responding to the needs 

and expectations of our customers. We believe in building long-term relationships through 
collaboration and trust. 

Continuous improvement in our products and services is the basis of our ability to satisfy 
both current and future customers. Our approach includes the development of evaluation 
methods and standards that offer the customer a guaranteed quality in terms of comfort, 
function, durability and price.

Through our team of skilled and dedicated employees, we are focused on supporting 
education, development and innovation within the healthcare profession. Our goals are to 
facilitate high quality care aimed at preventing pressure ulcers, to reduce healthcare related 
infections and to improve fire safety within healthcare environments. 

!

Содержание OptiCell 4 PRO

Страница 1: ...1 USER GUIDE OptiCell 4 PRO Alternating pressure air mattress...

Страница 2: ...roduct 8 Receiving and unpacking 8 Storage 8 Automatic adjustment and alternating pressure 9 Static mode 9 Low pressure alarm 9 Air hose connection 10 Hand Check test 11 Inspection and troubleshooting...

Страница 3: ...e CE marking signifies that OptiCell AB has the manufacturer s responsibility to ensure that this product meets the essential requirements of relevant European legislation This includes the provision...

Страница 4: ...ment of the intended usage environment and then use the right product Please contact us if you have any questions In order to avoid damage the mattress should not come into contact with heat sources o...

Страница 5: ...use maintenance and improved safety It is very important to read this guide carefully before using the product Care personnel must be given access to this user guide and also be informed of the risks...

Страница 6: ...the bi elastic surface layer reduces the risk of shear and other complications for the patient Fluid protection flap and waterproof zip on four sides with welded seams Anti slip underside which grips...

Страница 7: ...ell 4 PRO air mattress is connected to the pump by three air hoses The red air hose positioned in the middle is used to fill the head cells situated under the patient s head It also fills the lower ch...

Страница 8: ...n mind that a tall patient can weigh the same as a short patient but may need a different pressure This must always be carefully observed for each patient The biggest risk for the patient is to bottom...

Страница 9: ...not want to be disturbed by an alternating pressure Press the Care Static button position E on page 14 to select either Care mode or Static mode Care also called Auto firm mode provides maximum pressu...

Страница 10: ...connector if the air hose is disconnected from the pump To minimise the risk of air leakage during hose connection check That the two hooks are not damaged and their clips are intact That the black o...

Страница 11: ...t is easier for the staff but it may give an incorrect test result Fold away the sheets and unzip the mattress cover to access the cells Put one hand between two cells with the patient lying on the ma...

Страница 12: ...r hoses for signs of damage or abnormal wear Check the air hose connector see page 10 INSPECTION OFTHE OPTITEX COVER Regularly check the cover for visible signs of damage or wear such as tears cracks...

Страница 13: ...d at a minimum of 70 C for at least 10 minutes with unscented detergent according to standard BS EN 14065 2016 Textiles Laundry Processed Textiles Biocontamination Control System The OptiTex cover can...

Страница 14: ...ng on the mattress is affected by the comfort mode chosen Press this button to cycle through modes ALARM If the alarm sounds press this button to mute and reset The adjacent Leaking lamp will light up...

Страница 15: ...out condensation Storage 10 90 without condensation Safety standard CE marked CARE STATIC Press this button to select Care auto firm mode or Static mode When the adjacent Care lamp is lit the pump pro...

Страница 16: ...posed of at a recycling station and sorted as Combustible waste For more information contact J rven HealthCare J rven Health Care takes environmental responsibility seriously We strive to always use m...

Страница 17: ...COMPLAINTS Any complaints regarding the product must be notified in writing to J rven Health Care The return of products must be done in accordance with our instructions Returning a product before a c...

Страница 18: ...essment is made to identify the specific needs of the patient regarding pressure relief and must be conducted by staff with adequate knowledge and education Based on the patient s assessed status the...

Страница 19: ...19 YOUR NOTES If you require any further information or assistance please get in touch with us We will be happy to help you...

Страница 20: ...e OPTICELL 4 PRO user guide All trademarks are the property of their respective owners J rven AB reserves the right to update this guide if necessary and or on finding any spelling or factual errors A...

Отзывы: