46
*Cover open
*Errors such as abnormal head temperature etc.
(But when the recovery is impossible or the contents of buffer is lost, this function
will not be executed.)
・
If the quantity between the position of this control code and the position where
Paper end has been detected exceeds the capacity of printer buffer ( 16KB ), re-
Print will not be executed.
DC2 + “T”: Test printing
HEX:12 + 54
DEC:18 + 84
Setting this command, it starts test printing.
This command works as same as when pressing the feed button with power ON.
ESC + “P” + n:Valid judgement of feed SW
HEX:1B + 50 + n
DEC:27 + 80 + n
Judge the disposition of the feed SW whether it is valid.
N=0 Feed SW valid ( default value )
N=1 Feed SW unvalid
AX+”V”: Print status indication
HEX: 0B+56
DEC: 11+86
Prints the status of present setting.
Concerning print format, see the below and the print form of the next page.