8
Setting Kanji Code
SW1 ON
OFF
Kanji Code
Shift JIS
JIS Code
Setting Shift JIS
・
Without Kanji code (ESK + “K” ), ANK + Kanji code can be printed.
Setting JIS Code
・
Define the Kanji Code, it defines only Kanji Code.
・
Without defining Kanji Code or removing it, it defines only ANK font.
Table 3-2 : Baud Rate Setting
SW2
SW3
4800 ON OFF
19200 OFF
ON
9600 OFF OFF
Auto-setting ON
ON
Sending the following command, baud rate would be
automatically recognized.
$$$$$$$$$$$$
*:
24H x 12 + 24H x 1
Table 3-3 : Print Density
Print Density
SW4
SW5
Standard
OFF OFF
Thick (130%)
ON
OFF
Thicker (223%)
OFF
ON
Thin (70%)
ON
ON
Print Density would be changed by each thermal head.
Adjust it by SW4-5 or command (DC2 + “S” +n )
When exits the factory, setting of DIP Switches is as Table below shows.
No.
Switch
Contents
1
OFF
Kanji Code: JIS
2 OFF
3 OFF
Baud Rate : 9600 bps
4 OFF
5 OFF
Print Density : Normal
6 OFF
Normal
Printing
7 OFF
Ignored
8 OFF
Normal
Printing