![Japan Subcontract APM-N90 Скачать руководство пользователя страница 37](http://html1.mh-extra.com/html/japan-subcontract/apm-n90/apm-n90_user-manual_3346003037.webp)
35
DC3+”A”: Select ruler line A
HEX: 13+41
DEC: 19+65
Selects ruler line buffer A. ( default value )
DC3+”B”: Select ruler line B
HEX: 13+42
DEC: 19+66
Selects ruler line buffer B.
DC3+”V”+DATA: Write ruler line MSB image
HEX: 13+56+image data
DEC: 19+86+image data
Writes the image data into the selected ruler line buffer.
・
Same as the bit image, input the image data of 1 dot line.
・
The number of data per dot line=48 bytes
・
Data will be printed so that the most significant bit ( MSB ) appears on the left
margin.
DC3+”v”+DATA: Write ruler line LSB image
HEX: 13+76+image data
DEC: 19+118+image data
Writes the image data into the selected ruler line buffer.
・
Same as the bit image, inputs the image data of 1 dot line.
・
The number of data per dot line=48 bytes
・
Data will be printed so that the least significant bit ( LSB ) appears on the left
margin.
DC3+”D”+n1+n2: Set ruler line by dot
HEX: 13+44+n1+n2
DEC: 19+68+n1+n2
Prints the dots of n1 n2 in the selected ruler line buffer black.
・
n1 is lower-order byte and n2 is higher-order bytes.
0
≦
n1
≦<
FF
>
HEX
0
≦
n2
≦<
03
>
HEX
・
Set the position of the dot by [n2
≦
256+n1] taking the dot on the left end as 0.