21
TEMPERATURE SETTING
Temperature parameter represents the temperature of secondary water (heating water).
When red button “Setting” is pressed once, you enter the setup menu. Setpoint tempera-
ture of the heater can be adjusted by pressing buttons up or down. Values from 20°C to
99°C can be set. Adjusted value starts to blink on the screen. To apply the value press red
button once again.
After that you enter holding time setting. If you press red button once again you exit set-
tings and sign “---“ appears.
TEMPERATURE PARAMETER REPRESENTS THE TEMPERATURE OF SECONDARY
WATER (HEATING WATER). TEMPERATURE OF MILK IS LOWER AND MUST BE
MEASURED SEPARATELY!
MILK TEMPERATURE DEPENDS ON MILK VOLUME TO BE PASTEURIZED, TEMPE-
RATURE OF HEATING WATER AND ENVIRONMENT TEMPERATURE.
TIME SETTINGS (HOLDING TIME)
When red button “Setting” is pressed two times, you enter the setup menu of holding
time. Holding time is expressed in minutes. Here you set the holding time by pressing
buttons up or down, values from 0 to 999 can be set. Adjusted value starts to blink on
the screen. To apply the value press red button once. After applying holding time you exit
settings, sign “---“ appears.
TIME PARAMETER REPRESENTS THE HOLDING TIME.
WHEN SECONDARY WATER (HEATING WATER) REACHES SETPOINT TEMPERATURE,
CONTROL UNIT BEEPS AND ENTERS HOLDING PROCESS. AT HOLDING PROCESS,
SECONDARY WATER IS KEPT ON SETPOINT TEMPERATURE FOR A SETPOINT TIME!
Содержание Milky 13360
Страница 7: ...7 7 8 7 8 9 10...
Страница 13: ...13...
Страница 19: ...19 7 8 7 8 9 10...
Страница 25: ...25...
Страница 31: ...31 7 8 7 8 9 10...
Страница 37: ...37...
Страница 38: ...38...
Страница 39: ...39...