Page 5
ENGLISH
Jandy
®
JRT Series Heat Pumps
|
Installation and Operation Manual
Table 1. Jandy JRT Heat Pump Technical Specifications
MODEL
JRT2000R
JRT2500R
JRT3000R
VOLTAGE
208/230V/60HZ
208/230V/60HZ
208/230V/60HZ
OUTPUT (80/80/80)*
103,000 BTUs
116,000 BTUs
130,000 BTUs
INPUT (80/80/80)*
4.72 kW
5.23 kW
6.57 kW
COP (80/80/80)*
6.4
6.5
5.8
OUTPUT (80/63/80)**
96,000 BTUs
109,000 BTUs
124,000 BTUs
COP (80/63/80)**
6.1
6.1
5.6
OUTPUT (50/63/80)**
62,000 BTUs
70,000 BTUs
82,000 BTUs
COP (50/63/80)***
4.1
4.1
4.0
RLA (RUNNING LOAD AMPS)
28.3A
29A
32.5A
LRA (LOCKED ROTOR AMPS)
178A
145A
148A
MINIMUM CIRCUIT AMPACITY
38A
39A
40A
MAX OVER CURRENT PROTECTION#
40A
50A
50A
CHILLER FEATURE
YES
YES
YES
HOT GAS DEFROST
YES
YES
YES
HEAT EXCHANGER
Ti Twisted Coil
COMPRESSOR
Scroll
CABINET
ABS
MAXIMUM HEIGHT BELOW WATER LEVEL
10 feet
MINIMUM HEIGHT ABOVE WATER LEVEL
5 feet
OPTIMAL WATER FLOW
42 GPM
48 GPM
57 GPM
MINIMUM WATER FLOW
20 GPM
20 GPM
30 GPM
MAXIMUM WATER FLOW
70 GPM
AIR FLOW
3600 CFM
UNION SIZE
2” PVC Tail Piece / Nut
WEIGHT
232 lbs
242 lbs
252 lbs
* Rated in accordance with AHRI Standard 1160. Test Conditions: 80
˚
F Air, 80% RH, 80
˚ F Water.
** Rated in accordance with AHRI Standard 1160. Test Conditions: 80
˚
F Air, 63% RH, 80
˚ F Water.
*** Rated in accorance with AHRI Standard 1160. Test Conditions: 50˚F Air, 63% RH, 80˚F Water.
**** Max Over Current Protection refers to the maximum breaker size allowed. If this value is not a standard breaker size, use the next smallest standard size breaker.
The breaker size must not be smaller than the Minimum Circuit Ampacity value.