Page 3
ENGLISH
Jandy
®
FHP Pumps | Installation & Operation Manual
Section 1. Important Safety Instructions
READ AND FOLLOW ALL INSTRUCTIONS
1.1 Safety Instructions
All electrical work must be performed by a licensed electrician and conform to all national, state, and local codes.
When installing and using this electrical equipment, basic safety precautions should always be followed, including
the following:
WARNING
RISK OF SUCTION ENTRAPMENT HAZARD, WHICH, IF NOT AVOIDED, CAN RESULT IN SERIOUS INJURY
OR DEATH.
Do not block pump suction as this can cause severe injury or death. Do not use this pump for wading
pools, shallow pools or spas containing bottom drains, unless the pump is connected to at least two functioning
suction outlets. Suction outlet (drain) assemblies and covers must be certified to the latest published version of
ANSI
®
/ASME
®
A112.19.8, or its successor standard, ANSI/APSP-16.
WARNING
To reduce the risk of injury, do not permit children to use this product.
WARNING
To reduce the risk of property damage or injury, do not attempt to change the backwash (multiport, slide, or full
flow) valve position with the pump running.
WARNING
Jandy pumps are powered by a high voltage electric motor and must be installed by a licensed or certified
electrician or a qualified swimming pool service technician.
WARNING
RISK OF ELECTRIC SHOCK, FIRE, PERSONAL INJURY, OR DEATH
. Connect only to a branch circuit that is
protected by a ground-fault circuit-interrupter (GFCI). Contact a qualified electrician if you cannot verify that the
circuit is protected by a GFCI. A GFCI should be provided by the installer and should be tested on a routine basis.
To test the GFCI, push the test button. The GFCI should interrupt power. Push the reset button. Power should
be restored. If the GFCI fails to operate in this manner, the GFCI is defective. If the GFCI interrupts power to
the pump without the test button being pushed, a ground current is flowing, indicating the possibility of electrical
shock. Do not use the pump. Disconnect the pump and have the problem corrected by a qualified service
representative before using.
Due to the potential risk of fire, electric shock, or injuries to persons, Jandy pumps must be installed in
accordance with the National Electrical Code
®
(NEC
®
), all local electrical and safety codes, and the Occupational
Safety and Health Act (OSHA
®
). Copies of the NEC may be ordered from the National Fire Protection Association
®
(NFPA
®
) online at www.nfpa.org or call 617-770-3000, or contact your local government inspection agency.
WARNING
Incorrectly installed equipment may fail, causing severe injury or property damage.
WARNING
• Do not connect the system to an unregulated city water system or other external source of pressurized water
producing pressures greater than 35 PSI.
•
Trapped air in system can cause the filter lid to be blown off, which can result in death, serious personal injury,
or property damage. Be sure all air is out of the system before operating.