Figure 13. Control Center Front Panel
Section 5. Operating Instructions
1. Broadcast or Spread Salt into Shallow End of Pool. Do Not Add Salt through
Skimmers, Main Drain or Surge Tank.
2. Set Unit to "00" % for 24 Hours. The AquaPure must read "00" for 24 hours
after the salt has been added and circulated in the pool.
Boost - 24 Hour 100% Chlorine Production Cycle - Refer to Manual
- - - - To Enter Boost Mode Press and Hold "Temperature" Button for 10 Seconds
Pool Temperature - Temperature of Pool Water at Flow Sensor
CELL ON - Making Chlorine
CELL RESTING - Off Portion of Chlorine Production Cycle
FLOW - Water Flow Present
CELL REVERSING - Automatic Cleaning Cycle in Progress
ADD SALT - Salinity Should be 3.0 - 3.5 Grams / Liter
SERVICE - Refer to Manual -
- - - - To Silence Audible Service Alarm Press and Hold "Salinity" Button for 5 Seconds
DIRECTIONS FOR ADDING SALT
Power On
CELL ON
CELL RESTING
FLOW
CELL REVERSING
ADD SALT
SERVICE
CHLORINE
PRODUCTION RATE
C
D
A
B
?
?
Salinity
Pool
Temperature
- Boost -
5.1 Using the Front Panel Controls
Chlorine Production Rate
(more or less) Adjustment
Pressing the arrow button
A
or arrow button
B
will change the
CHLORINE PRODUCTION
in 5% increments. Generally,
adjustments to production should be made in 10% increments.
Salinity
Press the
Salinity
button
C
to check the salinity of the water in pool.
Boost
Press and hold the
Temperature
button
D
for 10 seconds to enter
the
Boost
mode (Note ‘
bo
’ will
fl
ash intermittently).
Boost
can be
used to set chlorine production to maximum (100%) for 24 hours
of operation. After 24 hours of chlorinator run time, chlorine
production will return to previous setting. To clear the
Boost
mode,
press and hold the
Temperature
button again for 10 seconds.
NOTE
The Chlorine Production Rate buttons can be used to adjust the output % when the AquaPure is controlled
by the AquaLink RS only when the AquaLink RS is placed into Service Mode. (This feature is available with
AquaPure front PCB fi rmware version 11230A05 or later. Your fi rmware revision number can be found on the
back of the front AquaPure PCB.) If arrow button
A
or arrow button
B
is pressed,
JA
in the AquaPure display
indicates that
the AquaLink RS is controlling the AquaPure and desired output percentages.
The Boost button at the AquaPure Control Panel will start Boost cycle when the AquaLink RS is online.