Page 15
Figure 11.
Wiring AquaPure Power to an AquaLink RS Power Center
Filter Pump Relay
Aux. 3 Relay
Load
2
Line
2
Load
1
Line
1
To AquaPure
(240 VAC)
To Breaker
Panel
To Filter Pump
240 VAC
AquaLink RS Power Center
3.6.1
Wiring to a Jandy AquaLink RS
In the AquaLink RS Power Center, wire the AquaPure power
directly
to the LOAD SIDE of the Filter Pump
relay (see Figure 11).
The Jandy AquaLink RS and AquaPure use a four (4) wire connection to communicate and can be wired up
to 500 feet apart. Any outdoor rated four (4) conductor cable, minimum 22 AWG, can be used. Locate the
appropriate screw terminals on the circuit board according to Figure 12. Wire the AquaPure from the red 4-
pin terminal bar to the AquaLink RS red 4-pin terminal bar (see Figure 12).
NOTE
The screw terminals are removable to aid in installation.
IMPORTANT
Attach the AquaPure wires to the like-numbered screw terminals on both the AquaPure and AquaLink
RS as shown in Figure 12.
Figure 12.
Wiring an AquaPure to an AquaLink RS Control System Network
Jandy
Power Center
Front PCB
Reverse Side
Test P oints
A t o K
Flow
Sensor
R
S
Test
Switches
Aux Board
H
ORP
24 VAC
Red BLK YEL GRN
OPTIONAL
4 3 2 1
RED
BLK
YEL
GRN
RED BLK YEL GRN
AquaLink
AquaPure
(Master)
Red, 4-Pin
Terminal Bar
1 2 3 4
3.6.2
Wiring Multiple AquaPure Units to a Jandy AquaLink RS
Only one AquaPure unit can be connected to the AquaLink RS network. Additional AquaPure units may be
wired to the Filter Pump relay, but not to the AquaLink RS red, 4-pin terminal bar.
Содержание AquaPure APURE700
Страница 2: ......