background image

Page 27

If you use a Pool Pump Timer.

  The Association of Pool & Spa Professionals (APSP) recommends that all 

water in a residential pool pass through the 

fi

 ltration system at least once every 12 hours (referred to as pool 

water turnover).  However, many factors have an effect on actual pump and 

fi

 lter system run times.  Pool 

size, source of water, direct sun light, indoor/outdoor, screened/unscreened, 

fi

 ltration system, cold or hot 

weather, swimmer load, rain, organic debris, algae, etc., are all factors which contribute to either more or 
less pool pump and 

fi

 lter system run times.  Because of these differences, it is extremely dif

fi

 cult to set an 

initial run time (starting point) for the pool pump and chlorinating system.

Try initially setting the Pool Pump Timer to 12 hours.  It will take a few days to get just the right pool 
pump operating time.  Adjust accordingly using the steps listed below ( Section 5.4.2, steps 1-5 ).  When 
the AquaPure is wired with a Pool Pump Timer (See page 6 Figure 2) 

results will vary greatly from one 

pool installation to the next, so this should be discussed with either the pool builder or the local pool 
professional.  The key points are:

•  Operate pool pump at least the minimum time needed for good 

fi

 ltration.

•  The Pool Pump Timer reduces energy consumption.

NOTE

  Exception - For Cold Weather Operation:  If the AquaPure is run 24 hours a day through the winter, extremely 

cold water temperatures can affect Cell life.  Sometimes it will be necessary to run the AquaPure at a very low 
production rate of 10% to 20% or to turn the unit off.  See Winterizing on page 29.

NOTE

  The generator only operates when the pump is running. During hot weather months you may need to increase 

pump run time to allow suffi cient chlorine production.

5.4 Startup

 5.4.1 

Shocking

Shocking (Super Chlorination) is recommended before pool startup. 

Start out with good pool water 

from the beginning.  The AquaPure will build up a suf

fi

 cient level of chlorine for sanitation in several hours.  

However, if pool water has a high demand from the startup the AquaPure will not be able to produce enough 
chlorine to reach break point chlorination.  So, it is best to super chlorinate from an outside source at the 
time of pool startup.  Then, wait until the chlorine level has returned to 1 to 3 PPM before turning on the 
AquaPure.

 5.4.2 

Apply 

Power

1.   Turn on the pool pump switch or Pool Pump Timer.  When the AquaPure is 

fi

 rst turned on (cold), 

the unit will beep. Next it will self-calibrate the Flow/Temp/Salinity Sensor. After going through an 
internal test and calibration, the LCD will display the current setting for Chlorine Production (00% to 
100%).  During the calibration period “Wait” will appear.  “Wait” means the unit is self calibrating and 
doing internal testing.  This usually takes less than 6 minutes.

2.    Check salinity level by pressing the 

Salinity

 button.  It should read between 3.0 gpl and 3.5 gpl.  If it 

does not then press the 

Salinity

 button two or three more times until the salinity reading stabilizes.  

NOTE

  If still less than 3.0 gpl refer to pages 18 through 20 and adjust salt level.  (Maintain the Recommended 

Salinity Level of 3.0 to 3.5 gpl).  If salinity is below 2.0 gpl the AquaPure will automatically turn the cell off 
until the salinity is raised above 2.0 gpl, since operating with low salt will damage Cell.  Likewise, if salinity is 
above the range of measurement the AquaPure will automatically turn the cell off until the salinity is lowered 
to a measurable level, since operating with high salt will damage the control center.  If salinity is greater than 
3.5 gpl, see Troubleshooting, page 30.

3.    Adjust the Chlorine Production to 50% by pressing the arrow button 

B

.

Содержание AquaPure APURE700

Страница 1: ...Pending Installation and Operation Manual WARNING FOR YOUR SAFETY This product must be installed and serviced by a professional pool spa service technician The procedures in this manual must be follo...

Страница 2: ......

Страница 3: ...6 Chlorine Testing 18 4 7 Salt NaCl sodium chloride 18 4 7 1 When to Add Salt 18 4 7 2 What Type of Salt to Use 18 4 7 3 How Much Salt to Use 19 4 7 4 How to Add Salt to the Pool 19 Section 5 Operati...

Страница 4: ...Such a GFCI should be provided by the installer and should be tested on a routine basis To test the GFCI push the test button The GFCI should interrupt power Push the reset button Power should be res...

Страница 5: ...t can withstand splash out of pool water containing chlorine and or salt and other water purification chemicals All metal components used in and around a pool should be of a high grade quality stainle...

Страница 6: ...ell The AquaPure electrolytic cell contains bipolar electrodes which perform the electrolysis and produce chlorine when energized with DC current Chlorine is generated as pool water containing salt pa...

Страница 7: ...Control ORP External Control Connector AquaLink RS485 Connector External Control ORP External Control Connector AquaLink RS485 Connector CAUTION Factory wired for 240 VAC service If available electric...

Страница 8: ...F approved All Purpose Cleaner Primer An NSF approved All Purpose Cement such as Weld On 794 793 3 2 Plumbing Configurations WARNING When using electrical products basic precautions should always be f...

Страница 9: ...or Orientation with Flow Direction 3 2 1 Recommended Cell and Sensor Orientation Shown below are four different cell and sensor orientations The third port on the cell is designed for installation of...

Страница 10: ...g Figure 3 shows cell and sensor configuration with flow direction Figures 4 and 5 illustrates the recommended plumbing configurations which result in the most reliable operation Note The AquaPure is...

Страница 11: ...on the backplate on the mounting surface Mark screw centers and drill four inch 6 35 mm holes spaced 10 3 8 inches 264 mm on the horizontal center and 6 3 8 inches 162 mm on the vertical center Instal...

Страница 12: ...fety and safety of equipment 3 4 Earth Bonding Grounding A solid copper 8 AWG 8 4 mm2 wire is recommended for connecting the control center to a Permanent Earth Ground connection that is acceptable to...

Страница 13: ...ngth of the electrolytic cell with the full unions is 16 Sensor Port Plug and Nut 2 pvc 2 pvc Figure 8 Flow Temp Salinity Sensor Cell Connector Flow Temp Salinity Sensor or Sometimes Not Covered Tempe...

Страница 14: ...er enclosure 11 Prior to reattaching front cover check the wiring Be sure the Flow Temp Salinity Sensor is plugged in The DC cord should be plugged in Also check the AC wiring CAUTION Do not overtight...

Страница 15: ...the AquaPure from the red 4 pin terminal bar to the AquaLink RS red 4 pin terminal bar see Figure 12 NOTE The screw terminals are removable to aid in installation IMPORTANT Attach the AquaPure wires t...

Страница 16: ...5 m3 capacity 4 2 Determining Pool Size Gallons of Water in Your Pool Rectangular Pools Average length feet x average width feet x average depth feet x 7 5 gallon capacity Circular Pools Diameter feet...

Страница 17: ...Metals some metals can cause loss of chlorine Also metals can stain your pool Have your local pool professional check for metals and recommend methods of removal 4 Chloramines should not be present i...

Страница 18: ...Compare the samples A higher level should be found at the pool return line The higher level at the pool return line indicates the AquaPure is producing chlorine 1 At the pool return line 2 18 inches...

Страница 19: ...alt be inadvertently added to the pool see Section 7 Troubleshooting NOTE To convert gpl grams per liter of a salt solution to PPM Parts Per Million of a salt solution multiply by 1000 i e 3 0 gpl sal...

Страница 20: ...and splash out of pool water containing chlorine and or salt and other water purification chemicals All metal components used in and around a pool should be of a high grade quality stainless steel Car...

Страница 21: ...lbs 132 kg 290 lbs 145 kg 320 lbs 159 kg 350 lbs 172 kg 380 lbs 186 kg 410 lbs 197 kg 435 lbs 210 kg 464 lbs 224 kg 493 lbs 237 kg 522 lbs 250 kg 551 lbs 263 kg 580 lbs 1 50 g l 57 kg 125 lbs 68 kg 1...

Страница 22: ...Salt Concentration Before Addition Salt Addition Required per 1000 gallon pool capacity 0 0 gpl 25 6 lbs 11 6 kg 1 5 gpl 12 8 lbs 5 8 kg 0 3 gpl 23 5 lbs 10 7 kg 1 8 gpl 10 7 lbs 4 8 kg 0 5 gpl 21 4...

Страница 23: ...tment Pressing the arrow button A or arrow button B will change the CHLORINE PRODUCTION in 5 increments Generally adjustments to production should be made in 10 increments Salinity Press the Salinity...

Страница 24: ...PRODUCTION in 5 increments Generally adjustments to production should be made in 10 increments AquaLink RS Power Center Press the Mode Select button to put the AquaLink RS in the Time Out mode Press...

Страница 25: ...rine Salinity Salinity is displayed along with the gpl grams per liter indicator when the Salinity button is depressed If a reading of HH appears the salinity is above 4 5 to 6 5 gpl depending on pool...

Страница 26: ...the desired setting press the Salinity button to confirm the new beeper volume setting The change will be stored in permanent memory If you do not wish to keep the change wait 5 seconds and the chang...

Страница 27: ...ne production 5 4 Startup 5 4 1 Shocking Shocking Super Chlorination is recommended before pool startup Start out with good pool water from the beginning The AquaPure will build up a sufficient level...

Страница 28: ...your manual in a safe place Increase Chlorine Production before party time and return to normal afterwards Increase Chlorine Production when temperature goes up Increase Chlorine Production when numb...

Страница 29: ...of 3 0 3 5 gpl for optimum performance of the AquaPure If additional salt is required follow the procedures and charts described on pages 17 through 20 If salt level does not rise after 24 hours see...

Страница 30: ...oes not need to be cleaned STOP THE CLEANING PROCESS go on to next step e Otherwise allow the cell to remain in the solution until the foaming has stopped However do not leave in acid for more than 1...

Страница 31: ...eeze damage to the Cell and Flow Temp Salinity Sensor by running pump continuously or winterize pool by draining water from pump filter and all intake and return lines Remove the cell clean and store...

Страница 32: ...llow to run for 24 hours Recheck If still too low Super Chlorinate with outside source Take pool water sample to Pool Professional See pages 22 and 25 Low Less than 2 5 gpl salt level in pool water Te...

Страница 33: ...ter cleaning procedures Obstruction in the AquaPure cell Remove cell for inspection Follow cleaning procedures See page 27 Flow Temp Salinity Sensor not installed properly Ensure that the Flow Temp Sa...

Страница 34: ...circuit board Cycle Power Water temperature too low Winterize your pool See page 29 All the above have been checked and indicator light is still on Contact your authorized service representative Prob...

Страница 35: ...rvice representative 171 Possible Backboard service condition Contact an authorized service representative 172 Flow Sensor service condition or flow sensor is unplugged Contact an authorized service r...

Страница 36: ...the digital display 1 Press and hold button D for 15 seconds third beep 2 Within 5 seconds momentarily press C to enter the Fahrenheit Celsius change mode 3 To toggle between Celsius and Fahrenheit pr...

Страница 37: ...URE700 Control Box Cover APURE1400 1 1 3 R0404300 Control Box Decal APURE Top 1 4 R0404400 Control Box Decal APURE Bottom 1 5 R0403900 PCB Front LED All Models Rev B10038 01 1 6 T1005 Transformer 50 6...

Страница 38: ...Screw 6 X 1 2 3 6 1 2 14 R0452300 R0452400 7 Blade Cell 3 Port Cell 14 Blade Cell 3 Port Cell Includes Cell Assy APure O Ring 2 231 DC 16Ft Power Cord Blk 1 3 1 16 R0452500 Port Sensor 3 Port Cell inc...

Страница 39: ...2 1 6 R0403800 Flow Sensor w 16 Cable 1 9 4 2 Port Electrolytic 1 Cell and Sensor Replacement Parts ABS White Unions Dwg Kit Description Qty 1 R0403400 R0403600 2 Port Cell PURE700 w 16 DC Cable 2 Por...

Страница 40: ...mum and maximum specifications 7 Use of non factory authorized parts or accessories in conjunction with the product s 8 Chemical contamination of combustion air or improper use of sanitizing chemicals...

Отзывы: