Page 14
5. Cut out a 13
⅞
” (352 mm) section of the 2” (50 mm) pipe to insert the Cell. See Figure 10.
6. Install the Flow/Temp/Salinity Sensor into the 3 -Port Cell.
7. Feed the connector end of the Flow/Temp/Salinity Sensor cable through the DC cord strain relief
fi
tting
located in the bottom of the control center chassis backplate.
Be certain the connector is clean and
dry
, then plug the cable into the connector on the control center Printed Circuit Board as shown on
page 6 Figure 2. (
Do not pull Flow/Temp/Salinity Sensor cable too tight, allow a little slack).
8. Plug the DC cord, in either direction, into the Cell stud terminals protruding from the Cell top. Make
sure that the plug is fully inserted and bottomed out on the housing.
9. Connect the DC cord to the control center. Feed the DC cord through the same strain relief
fi
tting
as the Flow/Temp/Salinity Sensor. Plug the DC cord into the two push-on connectors located on the
control center Printed Circuit Board as shown in Figure 2 on page 6.
CAUTION
Do not bury the AquaPure DC cord or Sensor cable directly in the ground. Direct burial can cause
damage to an electrical cord/cable.
10. Tighten strain relief
fi
tting screws for the Flow/Temp/Salinity Sensor cable and the DC cord.
Do not
pull Flow/Temp/Salinity Sensor cable or DC Cord too tight. Allow a little cable slack inside of
control center enclosure.
11. Prior to reattaching front cover, check the wiring. Be sure the Flow/Temp/Salinity Sensor is plugged
in. The DC cord should be plugged in. Also, check the AC wiring.
CAUTION
Do not overtighten the strain relief fi tting. Overtightening can cause damage to the Flow/Temp/Salinity
Sensor cable.
12. If disconnected, plug the ribbon cable attached to the front cover PC board into Printed Circuit Board
mounted on the backplate (See page 6 Figure 2). Now reattach the control center front cover to the
backplate.
3.6 Connection to an AquaLink® RS Control System
The Jandy AquaLink RS is a multi-function pool controller and can fully control the function of the
AquaPure chlorine generator. The AquaPure will display “JA” when a button is pressed at the AquaPure
while the Jandy AquaLink RS is in control. Adjustment of the AquaPure chlorine production rate or Boost
mode can be controlled from the main menu of the Jandy AquaLink RS or the AquaPure control box at
the equipment. Boost mode may be activated from the AquaPure while the AquaLink RS is online. The
AquaLink RS offers individual pool and spa settings for output %. Refer to the
AquaLink RS Owners
Manual
for more information. The AquaPure temperature, salinity, service codes, and LED indicators
operate as normal.
NOTE
The AquaPure Chlorine Generator will communicate with AquaLink RS using fi rmware versions JJ or
later
.
CAUTION
To avoid risk of damage to the equipment and possible injury, it is important to make sure the DC cable
connector is fully seated on the cell stud terminals.
Содержание AquaPure APURE700